| 2018-08-28 10:07:06 | 2ND REVIEW: |
| | 2017 FLORIDA BUILDING CODE 6TH EDITION |
| | 2017 FLORIDA BUILDING CODE - PLUMBING, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - ACCESSIBILITY, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - FUEL GAS, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - RESIDENTIAL, SIXTH EDITION |
| | 2017 FLORIDA BUILDING CODE - EXISTING BUILDING, SIXTH |
| | EDITION |
| | 2017 FLORIDA BUILDING CODE - ENERGY CONSERVATION, SIXTH |
| | EDITION |
| | |
| | GAS COMMENTS: |
| | |
| | |
| | |
| | PREVIOUS COMMENT NOT COMPLIED 2. TYPE OF GAS (LP OR |
| | NATURAL).WPB AMEND. TO FBC SEC. 107.2.1. THE RESPONSE |
| | LETTER LIST THE TYPE OF GAS AS LP THE NOTE ON THE PLAN |
| | DOES NOT LIST A TYPE OF GAS IT PLEASE CLARIFY |
| | |
| | PREVIOUS COMMENT NOT COMPLIED 3. SUBMIT CALCULATIONS |
| | FOR COMBUSTION AIR PER THE 2017 FBC-FUEL GAS CODE |
| | SEC.304.1, 614.6 (CLOTHES DRYERS) OR 2017 FBC-RES. SEC. |
| | G 2407.1 AND G2439.4 (CLOTHES DRYERS). NOT SHOWN ON P-3 |
| | AS INDICATED IN RESPONSE LETTER. |
| | |
| | PREVIOUS COMMENT PARTIALLY COMPLIED5. SUBMIT A DETAIL |
| | SHOWING THE TYPE OF VENT, LOCATION, SIZE, TERMINATION |
| | POINT, HEIGHT ABOVE THE ROOF AND ANCHORING DETAILS OF |
| | THE GAS VENT(S) PER 2017 FBC-FUEL GAS SECS. 502 THRU |
| | 505 OR 2017 FBC-RES. SEC.G2426 THROUGH G2439. PLEASE |
| | PROVIDE THE FOLLOWING THE SIZE OF VENT PIPING, THE |
| | LENGTH FROM GAS APPLIANCE TO TERMINATION POINT. |
| | |
| | PREVIOUS COMMENT NOT COMPLIED 7. PROVIDE AN ENGINEERED |
| | DETAIL DRAWING FOR THE WATER HEATER STAND SHALL BE |
| | RATED TO A MIN OF 1000LB. PER WPB AMEND TO FBC 107.2.1 |
| | . I COULD NOT LOCATE SHT. S-1 LISTED IN RESPONSE LETTER |
| | |
| | NEW COMMENT: |
| | |
| | 1. PROVIDE SIZING TABLE USED TO SIZE SYSTEM SHOW ON |
| | PLAN. WPB AMEND. TO FBC SEC. 107.2.1 AND FBC FG 402.4 |
| | |
| | 2. SHOW REGULATORS. DRIP LEG AND SHUT OFFVALVE ON RISER |
| | REQUIRED FOR 2LB SYSTEM. PER FBC FG 410.1 AND 410.2 |
| | |
| | 3. PROVIDE ROOF PLAN SHOWING GAS PIPING . WPB AMEND. TO |
| | FBC SEC. 107.2.1 |
| | |
| | 4. SHOW GAS PIPING TO THE METER ON THE RISER AND ALL |
| | CUT SECTIONS OF PIPING TO METER. WPB AMEND. TO FBC SEC. |
| | 107.2.1 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |