Plan Review Notes
Plan Review Notes For Permit 18050501
Permit Number 18050501
Review Stop B
Sequence Number 1
Notes
Date Text
2018-05-22 09:58:56PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SIXTH EDITION (2017)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE ADDRESS ON THE PLANS, 112 POTTER ROAD, DOES NOT
 MATCH THE ADDRESS LISTED ON THE APPLICATION, 120 POTTER
 ROAD. FBC 107.2.1
  
 2) NOTE: FBC-R4501.19 FINAL INSPECTION. FINAL
 ELECTRICAL AND BARRIER CODE INSPECTION SHALL BE
 COMPLETED PRIOR TO FILLING THE POOL WITH WATER.
  
 3) THE PROJECT IS LOCATED IN A SPECIAL FLOOD HAZARD
 AREA (AE FLOOD ZONE). THE POOL EQUIPMENT SHALL BE
 ELEVATED TO OR ABOVE THE FINISH FLOOR ELEVATION OF THE
 LIVING SPACE OF THE DWELLING UNIT. FBC-R322
  
 4) SUBMIT TWO SETS OF THE MANUFACTURER'S SPECIFICATIONS
 AND PRODUCT LISTING THAT SHOWS COMPLIANCE WITH UL 2017
 FOR THE WINDOW AND DOOR ALARMS. FBC 107.2.1.2