| Plan Review Notes For Permit 18050452 |
| Permit Number |
18050452 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-06-07 18:48:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | FBC R = FBC RESIDENTIAL | | | | | | 1. SCOPE NOT CLEAR. APPLICATION IS TO "RESTRIPE | | | PORTIONS OF THE PARKING LOT" - WHAT PORTIONS? FBC 107. | | | | | | 2. REVISE THE PLAN TO PROVIDE THE FOLLOWING | | | INFORMATION: | | | | | | TOTAL NUMBER OF PARKING SPACES | | | NUMBER OF ACCESSIBLE SPACES | | | LOCATION OF ACCESSIBLE ENTRANCES | | | LOCATION OF ACCESSIBLE SPACES AND ACCESS AISLES | | | SHOW ACCESSIBLE ROUTE FROM PUBLIC WAY | | | ACCESSIBLE ROUTE FROM ACCESSIBLE SPACE TO ACCESSIBLE | | | ENTRANCE | | | | | | SEE FBC 2014 ACCESSIBLITY 202.3 (ALTERATIONS), 208.2 | | | (PARKING SPACES), 502 (PARKING SPACES), 206 (ACCESSIBLE | | | ROUTE). | | | | | | 3. DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED FOR | | | PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED ORIGINALS | | | FS471. | | | | | | |
|