| 2018-08-27 10:48:07 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18050390 |
| | REVIEWED: AUGUST 27, 2018 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC EC = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1- IMPACT FEES |
| | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES |
| | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE |
| | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM |
| | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH |
| | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT |
| | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE |
| | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL |
| | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
| | |
| | -PENDING |
| | |
| | |
| | 2-6- OK. |
| | |
| | |
| | 7- SHEET A0.09 LIFE SAFETY FLOOR PLAN TYPICAL LEVEL: |
| | TRASH ROOM AND TRASH CHUTE NEED TO BE FIRE RATED. SEC. |
| | 713 FBC. |
| | |
| | 7-2 2-HR RATING WAS ADDED TO SHEET A6.04, BUT PLEASE |
| | ADD 2-HOUR RATING TO SHEET A-0.09 TO MATCH. |
| | |
| | |
| | 8-19- OK. |
| | |
| | |
| | 20-PROVIDE 2 HOUR FIRE RATED ASSEMBLY DETAILS AND |
| | SPECIFICATIONS FOR POURED CONCRETE SHEARWALLS AT |
| | STAIRWAYS AND ELEVATOR SHAFT. SEC. 713.4 FBC. DETAILS |
| | PROVIDED ON SHEET A8.01 IS FOR CONCRETE BLOCK WALLS |
| | ONLY. |
| | |
| | 20-2-PROVIDE FIRE RATED LISTED WALL TYPES TO BE USED IN |
| | ALL FIRE RATED WALL ASSEMBLIES. |
| | |
| | |
| | 23- PROVIDE PRODUCT APPROVAL AS REQUIRED BY FAC |
| | 61G20-3.001 FOR: |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL) |
| | |
| | A)FLAT ROOF SINGLE PLY ROOFING NOA 15-0203.23 |
| | SUBMITTED. CLEARLY MARK WHICH APPROVED ASSEMBLY IS |
| | GOING TO BE INSTALLED. NOTE: IF THE SELECTED ASSEMBLY |
| | DOESN'T MEET THE DESIGN PRESSURES FOR ALL ROOF ZONES, |
| | THEN SIGNED AND SEALED RAS 117 CALCULATIONS ARE |
| | REQUIRED. |
| | B)CONCRETE ROOF TILE NOA 16-0112.07: DESIGNER OF RECORD |
| | TO SPECIFY ROOF TILE FASTENING METHOD AS REQUIRED BY |
| | SEC. 107.2.1.1 CITY AMENDMENTS. IF SPECIFYING TILE |
| | ADHESIVE, THEN PROVIDE PRODUCT APPROVAL FOR LISTED |
| | ADHESIVE. |
| | C) OK. |
| | D) OK. |
| | E) CHUTE ALUMINUM CAP AS SHOWN ON PLANS. |
| | |
| | A-E-DEFERRED SUBMITTALS |
| | |
| | |
| | 24- OK. |
| | |
| | |
| | 25- PROVIDE COMPLETE TRUSS PACKAGE SUBMITTAL REVIEWED |
| | BY THE DESIGNER OF RECORD. SEC. 107.3.4.1 CITY |
| | AMENDMENTS. |
| | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED |
| | SUBMITTAL) |
| | |
| | -DEFERRED TRUSS SUBMITTAL |
| | |
| | |
| | 26-30- OK. |
| | |
| | 31- OK. |
| | |
| | 32- OK. |
| | |
| | |
| | 33- PROVIDE COMPLETE ENGINEERED DETAILS AND |
| | SPECIFICATIONS FOR THE CONSTRUCTION OF ALL THE ENTRY |
| | CANOPIES. SEC. 1601.1 FBC. |
| | |
| | -DEFFERED CANOPY SUBMITTAL |
| | |
| | |
| | 34- FLOORING UNDERLAYMENT (NOTE: THIS MAY BE SUBMITTED |
| | LATER AS A DEFERRED SUBMITTAL). |
| | 1- SOUND INSULATION MATERIAL: |
| | A) PROVIDE 2 COPIES OF THE FLAME SPREAD INDEX AND SMOKE |
| | DEVELOPED INDEX TEST DONE IN ACCORDANCE WITH ASTM E 84 |
| | OR UL 723 AS REQUIRED BY SEC. 720.1 OF FBC 6TH EDITION |
| | (2017). |
| | B) PROVIDE 2 COPIES OF THE SOUND TRANSMISSION CLASS |
| | (STC) TEST DONE IN ACCORDANCE WITH ASTM E 90 AS |
| | REQUIRED BY SEC. 1207.2 OF FBC 6TH EDITION (2017). |
| | C) PROVIDE 2 COPIES OF THE IMPACT INSULATION CLASS |
| | (IIC) TEST DONE IN ACCORDANCE WITH ASTM E 492 AS |
| | REQUIRED BY SEC. 1207.3 OF FBC 6TH EDITION (2017). |
| | |
| | -DEFFERED FLOORING SUBMITTAL |
| | |
| | |
| | 35- OK. |
| | |
| | 360- VALUATION DECLARED IN THE PERMIT APPLICATION IS |
| | LOW. SEC. 109.3 CITY AMENDMENTS. UPDATE VALUATION. |
| | SEC. 109.3 BUILDING PERMIT VALUATION. FOR PERMITTING |
| | PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS SHALL BE |
| | TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | -PLEASE PROVIDE EVALUATION BASED IN ICC 2018 VALUES |
| | |
| | |
| | 37- SEC. 110.7 CITY AMENDMENTS: SHORING. FOR THRESHOLD |
| | BUILDINGS, SHORING AND ASSOCIATED FORMWORK OR FALSEWORK |
| | SHALL BE |
| | DESIGNED AND INSPECTED BY A FLORIDA LICENSED |
| | PROFESSIONAL ENGINEER, EMPLOYED BY THE PERMIT HOLDER |
| | OR SUBCONTRACTOR, PRIOR TO ANY REQUIRED MANDATORY |
| | INSPECTIONS BY THE THRESHOLD BUILDING INSPECTOR. ALL |
| | SHORING AND RESHORING PROCEDURES, PLANS AND DETAILS |
| | SHALL BE SUBMITTED TO THE ENFORCEMENT AGENCY |
| | FOR RECORDKEEPING. EACH SHORING AND RESHORING |
| | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND |
| | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING |
| | DOCUMENTS BY THE CONTRACTOR. |
| | |
| | -DEFERRED SHORING/RE-SHORING SUBMITTAL |
| | (SEE THRESHOLD REVIEW FOR ADDITIONAL COMMENTS) |
| | |
| | |
| | 38-41 OK. |
| | |
| | |
| | SEE LIST BELOW FOR REQUESTED DEFERRED SUBMITTALS: |
| | 1-ROOFING-PENDING TILE ATTACHMENT AND PRODUCT APPROVAL |
| | AND ENHANCED NAILING (IF APPLICABLE). |
| | 2- THRASH CHUTE AND ALUMINUM CAP AS SHOWN ON PLANS. |
| | 3-TRUSS SUBMITTAL |
| | 4-CANOPY SUBMITTAL |
| | 5-FLOORING SUBMITTAL |
| | 6-THRESHOLD INSPECTION PLAN |
| | 7-SHORING/RE-SHORING SUBMITTAL |
| | 8-HANDRAIL/GUARDRAIL ENGINEERING |
| | |
| | |
| | |
| | |