| 2018-10-02 08:37:05 | ****CORRECTIONS**** |
| | W.P.B. PERMIT: 18050348 |
| | 3RD REVIEW: OCTOBER 2, 2018 |
| | |
| | DYLAN BATTLES |
| | BUILDING PLANS EXAMINER I |
| | [email protected] |
| | 561-805-6718 |
| | |
| | FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017) |
| | FBC AMENDED = FLORIDA BUILDING CODE,6TH EDITION (2017) |
| | FBC B = FBC BUILDING |
| | FBC EB = FBC EXISTING BUILDING |
| | FBC A = FBC ACCESSIBILITY |
| | FBC ENERGY = FBC ENERGY CONSERVATION |
| | FBC R = FBC RESIDENTIAL |
| | |
| | 1. OK |
| | |
| | 2. NO COMMENT RESPONSE SHEET PROVIDED SO I CAN?T SEE |
| | HOW A DRAINAGE PLAN IS BEING IMPLEMENTED TO MAINTAIN |
| | DRAINAGE WITH THE SITE. |
| | PLEASE PROVIDE SITE DRAINAGE PLAN ACCORDING TO THE |
| | FOLLOWING CODE REFERENCES-[FBC AMENDED 107.5][FBC |
| | 110.9][FBC R401.3] |
| | |
| | 3. FBC 110.9, PROVIDE A DETAIL TO SHOW HOW ADJACENT |
| | PROPERTIES WILL BE PROTECTED (SILT FENCE). |
| | |
| | 3. ADDITIONAL COMMENT-A SILT FENCE DETAIL CAN BE FOUND |
| | AT- |
| | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS |
| | /FORMS,-PERMITS-APPLICATIONS |
| | |
| | 4. OK |
| | |
| | 5. FBC R 311.2, REVISE PLAN TO SHOW ENTRY DOOR WITH |
| | MINIMUM 32" CLEAR WIDTH. |
| | |
| | 6. FBC 107, REVISE PLAN TO INCLUDE ALL DOOR SIZES |
| | (EXAMPLE; ENTRY DOOR, WIC). |
| | |
| | 7. FBC 107, FBC R 301, REVISE PLAN TO SHOW ALL WINDOW |
| | SIZES (EXAMPLE; ENTRY DOOR SIDELITE). |
| | |
| | 8. A1GH, DOOR FROM GARAGE TO GUEST HOUSE, REVISE PLAN |
| | TO SHOW COMPLIANCE WITH FBC R 303.5.1. |
| | |
| | 5-8. ADDITIONAL COMMENT-THESE CAN ALL BE ADDRESSED BY |
| | ADDING A WINDOW AND DOOR SCHEDULE. |
| | |
| | 9. A1ADD, A1GH, WALL BETWEEN GARAGE AND RESIDENCE, |
| | CLARIFY CONSTRUCTION AND INSULATION, FBC R 302.6. NOTE |
| | THAT INSULATION IS SHOWN GRAPHICALLY ON A PORTION OF |
| | THE WALL ON A1ADD; NOT CLEAR WHY THIS ISN'T CONTINUOUS |
| | ON ALL GARAGE WALLS SEPARATING GARAGE FROM RESIDENCE. |
| | |
| | 9. ADDITIONAL COMMENT-THIS COMMENT WAS BEACAUSE THERE |
| | IS INSULATION HATCH AT GARAGE WALL, BUT THE HATCH ISN?T |
| | APPLIED ALONG THE WHOLE GARAGE /HOUSE DIVIDING WALL. |
| | PLEASE SHOW THE INSULATION HATCHING TO SHOW CONTINUOUS |
| | THERMAL BARRIER. |
| | FOR CONSISTENCY CAN THE HATCH BE APPLIED TO BOTH NEW |
| | GARAGES, OR SHOW WALL TYPE DETAIL COMMON TO GARAGE |
| | SEPARATION. |
| | |
| | 10-12. OK |
| | |
| | NEW COMMENTS FROM GUEST HOUSE REMOVAL: |
| | |
| | 13. CONSOLIDATE THE AREA TABULATIONS. |
| | SHOW EXISTING UNDER AIR AND EXISTING TOTAL (3301 UNDER |
| | AIR AND 4298 TOTAL ACCORDING TO PROPERTY APPRAISERS) |
| | NEW ADDITION UNDER AIR AND NEW TOTAL. |
| | NEW TOTAL UNDER AIR AND NEW TOTAL SQ. FOOTAGE. |
| | THE NEW TABLE SHOULD REPLACE THE TABLES ON S-1, A-1 ADD |
| | AND A1 ADD-W. |
| | |
| | 14. CONSOLIDATE THE ENERGY CALCULATIONS. PUT ALL AREA, |
| | INCLUDING THE NEW SPACE CONNECTED THE PREVIOUS LAYOUTS, |
| | INTO ONE ENERGY CALCULATION SUBMITTAL. |
| | |
| | 15. SHEET C-1 REMOVE THE WORD GUEST HOUSE FROM TITLE |
| | BLOCK, MAIN TITLE AND DRAWING INDEX. |
| | |
| | 16. SHEET A-1 PROVIDE NEW SHEET W/O GUEST HOUSE IN THE |
| | TITLE BLOCK AND THE PBC STAMP FOR IMPACT WOULD NO |
| | LONGER BE VALID FOR THIS PROJECT. (SEE IMPACT REVIEW |
| | FOR COMMENTS ON IMPACT). |
| | |
| | 17. SHEET A-4 REMOVE GUEST HOUSE FROM TITLE BLOCK. |
| | |
| | 18. [FBC R302.10]PROVIDE CUT SHEET FOR ICYNENE(ICC-ES |
| | REPORT OR EQUAL) WITH THE TYPE SELECTED TO ESTABLISH |
| | THICKNESS NEEDED TO MEET REQUIRED R-VALUE, FLAME SPREAD |
| | INDEX AND SMOKE DEVELOPED INDEX. |
| | ICYNENE REQUIRES THERMAL BARRIER FROM ATTIC. IF THERE |
| | IS MECHANICAL EQUIPMENT IN THE SPACE THAN IT REQUIRES |
| | IGNITION BARRIER. |
| | |
| | 19. [FBC AMENDED 107.3.4.1]PROVIDE PRODUCT APPROVALS |
| | FOR ROOFING, OR INDICATE THAT YOU WOULD LIKE THEM |
| | DEFERED. |
| | 10/4/18 CUSTOMER REQUESTED DEFERAL AND R-STOP IS |
| | CHANGED TO "N" STATUS TO INDICATE THAT ROOFER WILL |
| | PROVIDE SUBMITTAL UNDER ROOFING SUB PERMIT. |
| | |
| | NOTE: |
| | -PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW |
| | EACH COMMENT IS BEING ADDRESSED. |
| | -ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW |
| | OF MATERIALS REQUESTED. |
| | -WHEN RESUBMITTING, PROVIDE TWO IDENTICAL COLLATED SETS |
| | OF DOCUMENTS FOR ISSUANCE. OLD SHEETS (BOTH SETS) |
| | SHOULD BE RETAINED IN THE PACKAGE; PLEASE DO NOT |
| | DISCARD ANY DOCUMENTS. THEY SHOULD BE BOUND TOGETHER |
| | SEPARATELY FROM THE TWO ISSUANCE SETS AND MARKED "VOID" |
| | OR "OLD SHEETS". PLEASE DO NOT STAMP THE PLANS VOID AS |
| | APPLICANTS ARE INADVERTENTLY STAMPING SHEETS THAT WE |
| | NEED "VOID", RENDERING THEM NOT USABLE. |
| | |