2018-06-07 17:58:48****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC R = FBC RESIDENTIAL
  
 1. FROM PREVIOUS LIST:
  
 ON THE ROOF PRODUCT APPROVAL, INDICATE WHICH ASSEMBLY
 IS PROPOSED. IF THE ASSEMBLY DESIGN PRESSURE DOES NOT
 MEET THE DESIGN PRESSURES FOR ZONES 2 AND 3,
 ENGINEERING FOR ENHANCED FASTENING IS REQUIRED.
  
 2ND REVIEW, THE ASSEMBLY SELECTED DOES NOT MEET THE
 DESIGN PRESSURE REQUIREMENT FOR ZONES 2 AND 3. PROVIDE
 RAS117 CALCULATIONS (SEE GENERAL LIMITATION #7 ON THE
 PRODUCT APPROVAL).
  
 OTHER PRODUCTS OK.
  