| Plan Review Notes For Permit 18050129 |
| Permit Number |
18050129 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-05-22 10:15:57 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC R = FBC RESIDENTIAL | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. PAGE S0.2 WIND DIAGRAM DOES NOT INCLUDE A FLAT ROOF, | | | AND PRESSURES ON THAT PAGE ARE TOO LOW FOR A FLAT ROOF. | | | CLARIFY LOCATION WHERE THE CERTAINTEED MODIFIED IS | | | PROPOSED, FBC 107, FBC B 1609. | | | | | | 2. THE ASSEMBLY PROPOSED (#11, PAGE 7 OF 10) FOR THE | | | SLOPE ROOF UNDERLAYMENT HAS A LIMITATION OF -75PSF; | | | SHEETS S0.2 REQUIRES -97.56 FOR THE OVERHANG ZONE. | | | | | | 3. THE ENGINEER'S REVIEW STAMP COVERS SOME OF THE | | | INFORMATION ON THE AC STAND ENGINEERING; PROVIDE A | | | CLEAN COPY. | | | | | | 4. AC STAND, INDICATE WHICH OPTION IS PROPOSED. ALSO | | | PROVIDE INFORMATION REGARDING THE UNIT TO SHOW | | | COMPLIANCE WITH FBC B 1510.10 (CLEARANCE). | | | | | | 5. EUROWALL, INDICATE WHICH PANEL WIDTH IS PROPOSED, | | | FBC B 1609. DP IS TO COMPLY WITH DESIGN PRESSURES | | | SPECIFIED ON SHEET S0.2. | | | | | | | | | | | | | | | |
|