| 2018-05-03 18:31:29 | 05/03/2018 1ST PLUMBING REVIEW**DENIED** |
| | |
| | NOTE - A COMPREHENSIVE REVIEW COULD NOT BE DONE AT THIS |
| | TIME AND ADDITIONAL PLAN REVIEW COMMENTS MAY BE |
| | GENERATED UPON THE RE-REVIEW OF SUBMITTED CORRECTIONS. |
| | |
| | 1. FLORIDA ENERGY EFFICIENCY CODE FORM R405-2014 SHOULD |
| | BE REFLECTED AS 2017 AND YOU WATER HEATER EF: 0.92 SEEM |
| | EXTREMELY HIGH PLEASE PROVIDE TANK-LESS MANUFACTURES |
| | SPECIFICATION. |
| | 2. ISOMETRIC RISER DIAGRAM DIRECTION FLOW OF THE |
| | SANITARY DRAINAGE IS INCORRECT, KITCHEN SHOW AN AIR |
| | ADMITTANCE VALVE AND DRAWN VENTED THROUGH ROOF, PLEASE |
| | CORRECT AND CLEARLY SHOWN ON ISOMETRIC WPB AMENDMENTS |
| | TO THE FBC SEC. 107.3.5.3 (11) RESIDENTIAL PLUMBING |
| | 3. WASHING MACHINE IS ON 2, YES IT IS TO CODE BUT |
| | RECOMMENDED THAT THE DRAIN LINE BE 3? AS THIS AFFECT |
| | WILL RESULT IN SUDS DOWNSTREAM. |
| | 4. THERE IS NO VALUE LISTED ON THE PLUMBING |
| | SUB-APPLICATION AND THE OVERALL VALUE IS LOW. WPB |
| | AMENDMENTS TO THE FBC 109.3 BUILDING PERMITS |
| | VALUATIONS. IF IN THE OPINION OF THE BUILDING OFFICIAL, |
| | THE CLAIMED VALUATION OF BUILDING, ALTERATION, |
| | STRUCTURE, ELECTRICAL, GAS, MECHANICAL OR PLUMBING |
| | SYSTEMS APPEARS TO BE UNDERESTIMATED ON THE |
| | APPLICATION, THE PERMIT SHALL BE DENIED UNLESS THE |
| | APPLICANT CAN SHOW DETAILED, QUANTITY ESTIMATES, AND/OR |
| | BONA FIDE SIGNED CONTRACTS (EXCLUDING LAND VALUE) TO |
| | MEET THE APPROVAL OF THE BUILDING OFFICIAL. FOR |
| | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS |
| | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, |
| | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, |
| | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, |
| | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY |
| | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST |
| | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS |
| | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | 5. SPRINKLER TIME SHOW ON SIDE OF HOUSE THIS REQUIRES A |
| | SEPARATE PERMIT AND INSPECTIONS. PLEASE MAKE NOTE ON |
| | THE PLANS. WPB AMENDMENTS TO THE FBC SEC. 107.2.1 |
| | INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | |
| | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN |
| | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES |
| | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE |
| | PREVIOUSLY REVIEWED SHEETS. |
| | |
| | LUIS A. CRESPO |
| | PLUMBING INSPECTOR / |
| | PLUMBING PLAN REVIEW |
| | [email protected] |
| | 561-805-6720 |
| | |