Plan Review Notes
Plan Review Notes For Permit 18041045
Permit Number 18041045
Review Stop P
Sequence Number 2
Notes
Date Text
2018-07-24 10:42:381) SHT.P.3.1.00 - SHOWS A FLAT, DRY VENT DOWNSTREAM OF
 OB-1. FLAT, DRY VENTS ARE NOT PERMITTED PER 2017 FBCR
 SEC. P3104.3.
 2) SHTS. P.3.0.00 & P.3.1.00 ARE MISLABELED IN THE
 DRAWINGS FOLDER.
 3) SHT.P.3.1.00 - THE SHOWER DOWNSTREAM OF THE WATER
 CLOSET IN THE MASTER BATH IS NOT PROPERLY VENTED. THE
 SHOWER MUST CONNECT TO THE HORIZONTAL DRAIN UPSTREAM OF
 THE WATER CLOSET OR BE INDIVIDUALLY VENTED.2017 FBCR
 SEC. P3101.2.1.
  