Plan Review Notes
Plan Review Notes For Permit 18041031
Permit Number 18041031
Review Stop B
Sequence Number 2
Notes
Date Text
2018-07-05 13:04:28****CORRECTIONS****
 W.P.B. PERMIT: 18041031
  
 FBC = FLORIDA BUILDING CODE, 6TH EDITION (2017)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC R = FBC RESIDENTIAL
  
 **NOTE THAT RESPONSE LETTER ENDS AT ITEM 16.
  
 1. SHEET A-0.0.01A WAS UPDATED TO SAY 2017, BUT IT
 STILL SAY FIFTH EDITION. WE ARE CURRENTLY USING THE
 SIXTH EDITION.
 ALSO, UPDATE SHEET A.3.2.01 GUTTER DETAIL REFERS TO OLD
 CODE.
  
 2. OK
  
 3. WHY SHOW 1HR RATING WHEN YOU MAKE SEPARATION
 DISTANCE TO USE ZERO HOURS? IF USING 1 HR SHOW UL WALL
 ASSEMBLE TO ACHIEVE THE SPECIFIED RATING.
 THE CODE REFERENCE ON SHEET A-0.0.01A FIRE RESISTANCE
 RATING REQUIREMENTS, THE CODE REFERENCE FBC R3.2.01
 SHOULD READ FBC R302.1
  
 4-5. OK
  
 6. ENERGY CALCULATIONS DATA SHEET SAYS 2 BEDROOMS.
 PLEASE UPDATE TO 3 BEDROOM.
 CROSS VENTILATION BOX SHOULD INDICATE "YES" CROSS
 VENTIALLATION BEING UTILIZED.
 [FBC ENERGY R402.1.2]GLAZING SHGC LEVELS FOR WINDOW A&B
 EXCEED ALLOWABLE VALUES IN TABLE R402.1.2 OF THE
 RESIDENTIAL ENERGY CODE FOR CLIMATE ZONE 1.
 CHECK MARKS AS APPLICABLE TO MANDATORY CHECKLIST.
  
 [FBC 302.10]PROVIDE CUT SHEET FOR THE PROPOSED
 INSULATION TO SHOW FLAME SPREAD INDEX, OR INDICATE THAT
 THEY WILL BE PROVIDED AS SUBMITTAL PRIOR TO
 INSTALLATION.
 SHOW IN PLAN SECTIONS,DETAILS AND WALL TYPES THE
 INSULATION BEING USED ,INCLUDING R-VALUE, SO IT IS NOT
 JUST REFERENCING "SEE ENERGY CALCS".
 [FBC R806.3]IF BLOWN IN INSULATION IS BEING USED, HOW
 WILL YOU PREVENT IT FROM BLOCKING CROSS VENTILLATION?
 SHOW/EXPLAIN ON PLANS.
  
 7-11. OK
  
 12. PARTIALLY ADDRESSED. ADD CRICKET DETAIL TO SECTIONS
 A-3.2.01 TO SHOW THAT CRICKET WILL BE ON BACK SIDE OF
 TOWER AS WELL AS SIDE.
  
 13-14. OK
  
 15. ADD NOTE THAT TYPICAL TRUSS ATTACHMENT USES TYPE
 "1" STRAP, OR LABEL EACH TRUSS TO SHOW EACH TRUSSES
 CONNECTOR DESIGNATION.
  
 16. OK
  
 ***COMMENT RESPONSE SHEET ENDED AT 16.***
  
 IN RE-SUBMITTAL PLEASE INCLUDE NEW RESPONSE SHEET FOR
 ALL COMMENTS.
  
 17) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS
 FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 ROOFING MATERIALS, WINDOW/GLASS TYPES, STRUCTURAL
 MULLIONS AND EXTERIOR DOOR TYPES.
  
 18) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE
 OUTDOOR STONE VENEER FACING. FBC 107.3.4
  
 19) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE OFF
 RIDGE ROOF VENTS (NOA 17-1031.03). FBC 107.3.4
  
 20) SUBMIT TWO SETS OF PRODUCT APPROVALS FOR THE 8"
 LINTELS. FBC 107.3.4
  
 21) THE PRODUCT APPROVAL NUMBERS LISTED ON THE PLANS
 FOR THE OVERHEAD GARAGE DOORS ARE FL NUMBERS NOT NOAS.
 PLEASE CORRECT.
  
 22) THE PRODUCT APPROVALS THAT WERE SUBMITTED FOR THE
 ENTRY DOOR HAVE A DIFFERENT NUMBER THAN THE ONE
 SPECIFIED ON THE PLANS. FL17-1031.03 IS LISTED ON THE
 PLANS. THIS IS A NOA NUMBER NOT AN FL. THE PRODUCT
 APPROVAL SUBMITTED IS FL15037.3. PLEASE COORDINATE. FBC
 107.2.1
 -01 DOOR ENTRY. MATCH N.O.A. NUMBER ON PLANS SHEET
 A-6.2.01 DOOR TYPE "C" TO MATCH THE N.O.A.
 PROVIDED(FL15037.3).
  
 23) INDICATE THE CEMENT ROOF TILE AND ATTACHMENT METHOD
 THAT WILL BE USED BY MARKING THE APPROPRIATE
 INFORMATION ON THE PLANS. FBC 107.2.1 IF AN ADHESIVE
 WILL BE USED, SUBMIT THE PRODUCT APPROVAL FOR IT. FBC
 107.3.4 IF A MORTAR OR ADHESIVE SET IS USED SUBMIT THE
 PRODUCT APPROVAL FOR THE UNDERLAYMENT TO SHOW THAT IT
 WILL MEET WINDLOADS. SEE INSTALLATION NOTE 6.2 ON PAGE
 5 OF THE TILE PRODUCT APPROVAL.
 PROVIDE N.O.A.'S FOR UNDERLAYMENT MATERIALS FOR CEMENT
 TILE ROOF.
  
  
 24) SUBMIT TWO SETS OF SIGNED AND SEALED TRUSS DRAWINGS
 AND TRUSS LAYOUT PLANS THAT HAVE BEEN REVIEWED AND
 APPROVED BY THE DESIGNER OF RECORD FOR THE PROJECT.
 FBC-R802.10
  
 25) PRODUCT APPROVALS WERE SUBMITTED FOR FIXED WINDOWS
 (NOA NO. 17-1212.13) AND STRUCTURAL MULLIONS (NOA NO.
 17-1212.24) AND NEITHER OF THESE ARE USED FOR THIS
 PROJECT. PLEASE CLARIFY. FBC 107.2.1
 NOT ADDRESSED. REMOVE N.O.A.'S IF NOT BEING USED.
  
 26. IN RE-SUBMITTAL PLEASE INCLUDE NEW RESPONSE SHEET
 FOR ALL COMMENTS.
  
 27. [FBC R302.11]ADD FIREBLOCKING TO DETAIL ON TYPICAL
 WALL SECTION.
  
 28. [FBC 302.3.1] IT IS SUGGESTED TO ADD A NOTE TO DOOR
 SCEHDULE TO SHOW WHAT IS BEING PROVIDED FOR DOOR 116C.
  
 NOTE:
 ADDITIONAL COMMENTS MAY BE FORTHCOMING PENDING REVIEW
 OF MATERIALS REQUESTED.
 PLEASE PROVIDE TWO IDENTICAL COPIES OF ALL ITEMS
 SUBMITTED.
  
  
  
  
  