2018-05-29 16:35:141ST REVIEW FBC-2017 MECHANICAL
 PERMIT #18041013
 5/29/18
  
 CODES IN EFFECT:
 FBC B- FLORIDA BUILDING CODE SIXTH EDITION 2017
 FBC M- FLORIDA MECHANICAL CODE SIXTH EDITION 2017
 FBC EC- FLORIDA ENERGY CONSERVATION CODE SIXTH EDITION
 2017
 FBC R- FLORIDA RESIDENTIAL CODE SIXTH EDITION 2017
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC-SIXTH
 EDITION 2017
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE COMPLETE MECHANICAL PLANS FOR THE NEW BAR
 TRAILER INCLUDING:
  
 MINIMUM VENTILATION CALCULATIONS- TABLE 403.1.1 FBC M.
 AC COOLING AND HEATING CALCULATIONS- SECTION 403.2.1
 FBC EC.
 AC EQUIPMENT SCHEDULE- C403.1 FBC EC
 AC DUCT LAYOUT PLAN- 601.1 FBC M
 ENERGY CALCULATIONS- SECTION C401.2 FBC EC
 EQUIPMENT SCHEDULES FOR THE NEW COOLERS- 1101.2 FBC M
 WINDLOAD ENGINEERING FOR INSTALLATION OF ALL EXTERIOR
 MECHANICAL EQUIPMENT OR APPLIANCES- 301.15 FBC M.
  
 2) PLEASE REFER TO FLORIDA ADMINISTRATIVE CODESECTION
 9B-1.011 ALTERATIONS AND RELOCATION, ITEMS 1-5 AS THEY
 RELATE TO THE ONSITE WORK PERFORMED ON THE TRAILER. IN
 ACCORDANCE WITH ITEM #3 THE ALTERED TRAILER SHALL
 COMPLY WITH THE CURRENT FLORIDA BUILDING CODES IN
 EFFECT AND COMPLETE INSPECTIONS OF ALL MODIFICATIONS
 MUST BE PERFORMED.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT
 CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE
 PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND
 KEEP THEM WITH THE SUBMITTALS
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
  


Account Summary | Usage Policy | Privacy Policy