Plan Review Notes
Plan Review Notes For Permit 18040256
Permit Number 18040256
Review Stop P
Sequence Number 1
Notes
Date Text
2018-04-12 19:18:2404/12/2018 1ST PLUMBING REVIEW**DENIED**
  
 1) STUDIO BATHROOM IS SHOWING A OVERALL MEASURMENT OF
 4' 6". THE MIN REQUIRED WOULD BE 5' (60") FINISHED TO
 COMPLY WITH FBC-R P2705. EACH FIXTURE REQUIRES 30"
 OVERALL. YOUR ROOM IS 6" TO SMALL.
  
 2) SHOW 2ND TANKLESS LOCATION. FBC 107.2.1
  
 3) EXPLAIN HOW YOU INTEND TO HAVE ACCESS TO THE SHUT
 OFF VALVES OR THE WASHING MACHINE TO COMPLY WITH FBC-R
 P2903.9.3
  
 TIM HUNT
 PLUMBING INSPECTOR / PLUMBING PLAN REVIEWER