Plan Review Notes
Plan Review Notes For Permit 18040256
Permit Number 18040256
Review Stop M
Sequence Number 1
Notes
Date Text
2018-04-18 13:07:51HEAT LOAD REQUIRED
  
 PER FBC. ENERGY CONSERVATION, SIXTH EDITION 2017
 R403.7.1 EQUIPMENT SIZING. HEATING AND COOLING
 EQUIPMENT SHALL BE SIZED IN ACCORDANCE WITH ACCA MANUAL
 S BASED ON THE EQUIPMENT LOADS CALCULATED IN ACCORDANCE
 WITH ACCA MANUAL J OR OTHER APPROVED HEATING AND
 COOLING CALCULATION METHODOLOGIES, BASED ON BUILDING
 LOADS FOR THE DIRECTIONAL ORIENTATION OF THE BUILDING.
  
  
  
 ENERGY COMPLIANCE REPORT REQUIRED
  
 PER FBC. ENERGY CONSERVATION, SIXTH EDITION 2017
 R405.4.2.1 COMPLIANCE REPORT FOR PERMIT APPLICATION.
  
  
  
 CHRIS MONTELLO
 561-805-6733
 [email protected]
  
  