| Date |
Text |
| 2019-03-26 15:43:36 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2017 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | JOSEAN A. DUPREY E.I., BN, PX |
| | BUILDING PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6716 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 4TH REVIEW |
| | RESULTS: DENIED |
| | YOUR SUBMITTAL IS DEFICIENT FOR THE REASONS LISTED |
| | BELOW. |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | |
| | 1. SEE COMMENTS FROM PREVIOUS LIST. A DETAIL SHOWING |
| | HEIGHT OF THE AWNING WAS PROVIDED. HOWEVER THE AWNING |
| | EXTEND MORE THAN 5 FEET OVER PUBLIC PROPERTY. PROVIDE |
| | DEPTH AND HEIGHT MEASUREMENTS. FBC 3105.3.1.4 MOVABLE |
| | FABRIC AWNINGS OR FABRIC COVERED FRAMES MAY EXTEND OVER |
| | PUBLIC PROPERTY FOR A DISTANCE OF NOT MORE THAN 5 FEET |
| | (1524 MM), PROVIDED SUCH AWNINGS OR ANY PART THEREOF |
| | MAINTAIN A CLEAR HEIGHT OF 8 FEET (2438 MM) ABOVE THE |
| | SIDEWALK. ALL SUCH MOVABLE AWNINGS SHALL BE SUPPORTED |
| | ON METAL FRAMES ATTACHED TO THE BUILDING. |
| | |
| | 2. 3. PROVIDE AWNINGS FABRIC FLAME SPREAD CRITERA. FBC |
| | 3105.3.4.1 FABRIC USED FOR AWNINGS OR FABRIC-COVERED |
| | FRAMES SHALL MEET THE FLAME PROPAGATION PERFORMANCE |
| | CRITERIA OF NFPA 701 OR HAVE A FLAME SPREAD INDEX NOT |
| | GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E84 |
| | OR UL 723. |
| | |
| | |
| | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: |
| | |
| | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 |
| | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. |
| | |
| | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED |
| | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS |
| | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE |
| | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE |
| | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR |
| | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN |
| | THE PERMIT PACKAGE. |
| | |
| | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS |
| | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. |
| | |
| | A THOROUGH REVIEW COULD NOT BE COMPLETED AT THIS TIME, |
| | AS A RESULT OF THE ADDITIONAL INFORMATION REQUESTED. |
| | ADDITIONAL COMMENTS MAY APPEAR THAT WERE NOT PART OF |
| | THIS REVIEW. |
| | |
| | |
| | |
| | |