| Date |
Text |
| 2018-05-17 11:15:02 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. THE WALLS AROUND THE MOP SINK IN JANITORS ROOM SHALL |
| | COMPLY WITH FBC 1210.2.2 WALLS AND PARTITIONS.WALLS AND |
| | PARTITIONS WITHIN 2 FEET OF SERVICE SINKS, URINALS AND |
| | WATER CLOSETS SHALL HAVE A SMOOTH, HARD, NONABSORBENT |
| | SURFACE, TO A HEIGHT OF NOT LESS THAN 4 FEET ABOVE THE |
| | FLOOR, AND EXCEPT FOR STRUCTURAL ELEMENTS, THE |
| | MATERIALS USED IN SUCH WALLS SHALL BE OF A TYPE THAT IS |
| | NOT ADVERSELY AFFECTED BY MOISTURE. |
| | |
| | 2. SHT. A602 PLEASE PROVIDE DIMENSIONS FOR THE |
| | EMERGENCY SCUPPER IT SHALL COMPLY WITH FBC 1503.4.2.1 |
| | OVERFLOW SCUPPERS. WHEN OTHER MEANS OF DRAINAGE OF |
| | OVERFLOW WATER IS NOT PROVIDED, OVERFLOW SCUPPERS SHALL |
| | BE PLACED IN WALLS OR PARAPETS NOT LESS THAN 2 INCHES |
| | NOR MORE THAN 4 INCHES ABOVE THE FINISHED ROOF COVERING |
| | AND SHALL BE LOCATED AS CLOSE AS PRACTICAL TO REQUIRED |
| | VERTICAL LEADERS OR DOWNSPOUTS OR WALL AND PARAPET |
| | SCUPPERS. AN OVERFLOW SCUPPER SHALL BE SIZED IN |
| | ACCORDANCE WITH THE FLORIDA BUILDING CODE, PLUMBING. |
| | |
| | 3. SHT. A202 DETAIL #1 THE LOBBY COFFEE BAR SHALL |
| | COMPLY WITH FBC ACC 606.2 AND 606.3 HEIGHT. LAVATORIES |
| | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE |
| | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM |
| | ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 4. P2.1 THE HD IN CHILLER ENCLOSURE SHALL BE COVERED TO |
| | PREVENT STORM WATER FROM DISCHARGING TO THE SANITARY |
| | SYSTEM AND CONDENSATE SHALL NOT DISCHARGE INTO THE |
| | SANITARY. PER CITY OF WEST PALM BEACH CODE OF |
| | ORDINANCES SEC. 90-126(5) |
| | |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |