| 2018-04-02 12:05:36 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS |
| | CODE: FBC 6TH EDITION (2017). |
| | |
| | 1- PROVIDE COMPLETE DRAWINGS DRAWN TO SCALE AND SHOWING |
| | COMPLIANCE WITH ALL THE LOADS AS REQUIRED BY SEC. |
| | R301.1 FBC-RESIDENTIAL. CONSTRUCTION DOCUMENTS TO |
| | SPECIFY ALL OPENINGS DIMENSIONS, REINFORCEMENT OF |
| | OPENING TO BE WIDENED INCLUDING, STRUCTURAL BEAM, ETC. |
| | ALSO, SPECIFY WINDOWS DESIGN PRESSURES. |
| | |
| | DESIGN CRITERIA |
| | SEC. R301.1 APPLICATION. |
| | BUILDINGS AND STRUCTURES, AND PARTS THEREOF, SHALL BE |
| | CONSTRUCTED TO SAFELY SUPPORT ALL LOADS, INCLUDING DEAD |
| | LOADS, LIVE LOADS, ROOF LOADS, FLOOD LOADS, SNOW LOADS, |
| | WIND LOADS AND SEISMIC LOADS AS PRESCRIBED BY THIS |
| | CODE. THE CONSTRUCTION OF BUILDINGS AND STRUCTURES IN |
| | ACCORDANCE WITH THE PROVISIONS OF THIS CODE SHALL |
| | RESULT IN A SYSTEM THAT PROVIDES A COMPLETE LOAD PATH |
| | THAT MEETS THE REQUIREMENTS FOR THE TRANSFER OF LOADS |
| | FROM THEIR POINT OF ORIGIN THROUGH THE LOAD-RESISTING |
| | ELEMENTS TO THE FOUNDATION. BUILDINGS AND STRUCTURES |
| | CONSTRUCTED AS PRESCRIBED BY THIS CODE ARE DEEMED TO |
| | COMPLY WITH THE REQUIREMENTS OF THIS SECTION. |
| | |
| | 2- PROVIDE COMPLETE FLOOR PLANS SHOWING THE NEW LAUNDRY |
| | ROOM DIMENSIONS/ FRAMING AND COMPLETE |
| | PLANS/SPECIFICATIONS FOR THE KITCHEN REMODELING. AND, |
| | DRAWINGS TO HAVE THE NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN AS REQUIRED BY SEC. 107.2.1 |
| | CITY AMENDMENTS. |
| | |
| | SEC. 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | ELECTRONIC MEDIA DOCUMENTS SHALL BE |
| | SUBMITTED WHEN APPROVED BY THE BUILDING OFFICIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT |
| | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF |
| | THE WORK PROPOSED AND SHOW IN DETAIL |
| | THAT IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND |
| | RELEVANT LAWS, ORDINANCES, RULES AND |
| | REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL. |
| | SUCH DRAWINGS AND SPECIFICATIONS SHALL |
| | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, |
| | AS TO THE QUALITY OF MATERIALS, WHERE |
| | QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL |
| | CODES. SUCH INFORMATION SHALL BE SPECIFIC, |
| | AND THE TECHNICAL CODES SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR SHALL THE TERM "LEGAL" OR |
| | ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR SPECIFIC |
| | INFORMATION. ALL INFORMATION, DRAWINGS, |
| | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE |
| | NAME AND SIGNATURE OF THE PERSON |
| | RESPONSIBLE FOR THE DESIGN. (SEE ALSO SECTION 107.3.5). |
| | |
| | 3- PROVIDE PRODUCT APPROVAL (2 COPIES) AS REQUIRED BY |
| | FAC 61G20-3.001 FOR: |
| | A) NEW WINDOWS A SHOWN ON PLANS. |
| | |
| | B) WINDOW MULLIONS AS SHOWN ON PLANS. AND, CLEARLY MARK |
| | SIZE OF MULLION TO BE USED TO VERIFY COMPLIANCE WITH |
| | THE DESIGN PRESSURES. COORDINATE WITH ITEM #1 ABOVE. |
| | |
| | 4- PROVIDE STRUCTURAL BUCK DETAILS FOR NEW WINDOWS. |
| | SEC. R609.7.2.1 FBC-RESIDENTIAL. |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | |