| Plan Review Notes For Permit 18030448 |
| Permit Number |
18030448 |
|
| Review Stop |
FIRE |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-03-14 16:34:10 | | | | | | | | | | 1) STAIRS INDICATED AT DOOR D 102 DO NOT APPEAR TO MEET | | | THE REQUIRMENTS OF NFPA 101. | | | | | | PER NFPA 101, CHAPTER 38, NEW BUSINESS | | | | | | 38.2.2.3 STAIRS. | | | 38.2.2.3.1 STAIRS COMPLYING WITH 7.2.2 SHALL BE | | | PERMITTED | | | | | | 7.2.2 STAIRS. | | | 7.2.2.1 GENERAL. | | | 7.2.2.1.1 STAIRS USED AS A COMPONENT IN THE MEANS OF | | | EGRESS SHALL | | | CONFORM TO THE GENERAL REQUIREMENTS OF SECTION 7.1 AND | | | TO THE | | | SPECIAL REQUIREMENTS OF 7.2.2, UNLESS OTHERWISE | | | SPECIFIED IN | | | 7.2.2.1.2. | | | | | | 7.2.2.3.6* DIMENSIONAL UNIFORMITY. | | | 7.2.2.3.6.1 VARIATION IN EXCESS OF 3?16 IN. (4.8 MM) IN | | | THE SIZES OF | | | ADJACENT TREAD DEPTHS OR IN THE HEIGHT OF ADJACENT | | | RISERS SHALL BE | | | PROHIBITED, UNLESS OTHERWISE PERMITTED IN 7.2.2.3.6.3. | | | 7.2.2.3.6.2 THE VARIATION BETWEEN THE SIZES OF THE | | | LARGEST AND SMALLEST | | | RISER OR BETWEEN THE LARGEST AND SMALLEST TREAD DEPTHS | | | SHALL NOT EXCEED ? | | | IN. (9.5 MM) IN ANY FLIGHT. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|