| 2018-03-23 10:16:29 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.4 SEATS. THE |
| | SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH FLOOR |
| | SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES (485 |
| | MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| | |
| | 2. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 |
| | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. PER FBC ACC 604.7 |
| | |
| | 3. GRAB BARS TO BE MEASURED TO THE TOP OF THE GRIPPING |
| | SURFACE OFF FINISHED FLOOR. PER FBC ACC 609.4 |
| | |
| | 4. PLEASE SHOW COMPLIANCE WITH THE REQUIREMENT FOR A |
| | WATER FOUNTAIN. PER FBC PL TABLE 403.1 |
| | |
| | 5. SHT. A-3 UNDER NOTE SCOPE OF WORK IN EXISTING |
| | BATHROOM THERE ARE NO EXISTING BATHROOMS SHOWN IN AREA |
| | OF WORK PLEASE CLARIFY WHERE THIS WORK IS BEING DONE. |
| | PER WPB AND TO FBC 107.2.1 |
| | |
| | 6. PLEASE STATE ON THE PLAN WHAT LEVEL OF ALTERATION |
| | THIS PROJECT IS PER FBC EX CH 2 |
| | |
| | 7. SHOW COMPLIANCE WITH FBC PL 607.3 |
| | |
| | 8. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES |
| | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET |
| | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND |
| | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN |
| | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT |
| | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 |
| | |
| | 9. WHAT TYPE OF PIPE IS SHOWN ON THE FIRE STOPPING |
| | DETAILS PROVIDE DETAILS FOR ALL TYPES OF PIPE AND |
| | INSTALLATIONS PER WPB AMEND TO FBC 107.2.1.3 |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |