| 2018-03-12 17:37:10 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE, 6TH EDITION W/2010 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. PROVIDE COPY OF APPROVAL LETTER FROM ARMY CORP OF |
| | ENGINEER'S. |
| | 2. SUBMITTED SURVEY IS NOT VALID UNLESS SEALED WITH AN |
| | EMBOSSED SURVEYORS SEAL. (SEE NOTE # 3) |
| | 3. DATE OF BOAT SHOW ON SURVEY STATES MARCH 22, 2017 |
| | THRU MARCH 25, 2018. PLEASE CLARIFY. |
| | 4. APPLICANT SHALL COMPLY WITH THE REQUIREMENTS OF FBC |
| | CHPT. 31, SECTION 3103 TEMPORARY STRUCTURES. |
| | |
| | SECTION3103 |
| | TEMPORARY STRUCTURES |
| | |
| | 3103.1 GENERAL. |
| | THE PROVISIONS OF SECTIONS 3103.1 THROUGH 3103.4 SHALL |
| | APPLY TO STRUCTURES ERECTED FOR A PERIOD OF LESS THAN |
| | 180 DAYS. TENTS AND OTHER MEMBRANE STRUCTURES ERECTED |
| | FOR A PERIOD OF LESS THAN 180 DAYS SHALL COMPLY WITH |
| | THE FLORIDA FIRE PREVENTION CODE. THOSE ERECTED FOR A |
| | LONGER PERIOD OF TIME SHALL COMPLY WITH APPLICABLE |
| | SECTIONS OF THIS CODE. |
| | |
| | 3103.1.1 CONFORMANCE. |
| | TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE |
| | STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS, |
| | ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY |
| | REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC |
| | HEALTH, SAFETY AND GENERAL WELFARE. |
| | |
| | 3103.1.2 PERMIT REQUIRED. |
| | TEMPORARY STRUCTURES THAT COVER AN AREA GREATER THAN |
| | 120 SQUARE FEET (11.16 M2), INCLUDING CONNECTING AREAS |
| | OR SPACES WITH A COMMON MEANS OF EGRESS OR ENTRANCE |
| | THAT ARE USED OR INTENDED TO BE USED FOR THE GATHERING |
| | TOGETHER OF 10 OR MORE PERSONS, SHALL NOT BE ERECTED, |
| | OPERATED OR MAINTAINED FOR ANY PURPOSE WITHOUT |
| | OBTAINING A PERMIT FROM THE BUILDING OFFICIAL. |
| | |
| | 3103.2 CONSTRUCTION DOCUMENTS. |
| | A PERMIT APPLICATION AND CONSTRUCTION DOCUMENTS SHALL |
| | BE SUBMITTED FOR EACH INSTALLATION OF A TEMPORARY |
| | STRUCTURE. THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A |
| | SITE PLAN INDICATING THE LOCATION OF THE TEMPORARY |
| | STRUCTURE AND INFORMATION DELINEATING THE MEANS OF |
| | EGRESS AND THE OCCUPANT LOAD. |
| | |
| | 3103.3 LOCATION. |
| | TEMPORARY STRUCTURES SHALL BE LOCATED IN ACCORDANCE |
| | WITH THE REQUIREMENTS OF TABLE 602 BASED ON THE |
| | FIRE-RESISTANCE RATING OF THE EXTERIOR WALLS FOR THE |
| | PROPOSED TYPE OF CONSTRUCTION. |
| | |
| | 3103.4 MEANS OF EGRESS. |
| | TEMPORARY STRUCTURES SHALL CONFORM TO THE MEANS OF |
| | EGRESS REQUIREMENTS OF CHAPTER 10 AND SHALL HAVE AN |
| | EXIT ACCESS TRAVEL DISTANCE OF 100 FEET (30 480 MM) OR |
| | LESS |
| | |