| 2018-04-27 08:28:41 | RESIDENTIAL (R3) REVISION, SECOND PLUMBING REVIEW |
| | CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- PLUMBING RISER DIAGRAM SUBMITTED SHOWS 2 WET VENTED |
| | FIXTURES DRAINS DISCHARGING UPSTREAM OF THE DRY VENTED |
| | FIXTURE DRAIN CONNECTION. REVISE AS REQUIRED. |
| | |
| | RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4 |
| | TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON |
| | NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM ONLY |
| | REVISED BATHROOM #2. BATHROOM #1 STILL DOESN'T COMPLY. |
| | REVISE AS REQUIRED. |
| | |
| | ARCHITECTS-ENGINEERS |
| | FLORIDA STATUTE 553.80(2)(B): |
| | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' |
| | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
| | |
| | |
| | SEC. P3108.2.1 FBC-RESIDENTIAL. HORIZONTAL WET VENT. |
| | THE DRY-VENT CONNECTION FOR A HORIZONTAL WET-VENT |
| | SYSTEM SHALL BE AN INDIVIDUAL VENT OR A COMMON VENT FOR |
| | ANY BATHROOM GROUP FIXTURE, EXCEPT AN EMERGENCY FLOOR |
| | DRAIN. WHERE THE DRY VENT CONNECTS TO A WATER CLOSET |
| | FIXTURE DRAIN, THE DRAIN SHALL CONNECT HORIZONTALLY TO |
| | THE HORIZONTAL WET VENT SYSTEM. NOT MORE THAN ONE |
| | WET-VENTED FIXTURE DRAIN SHALL DISCHARGE UPSTREAM OF |
| | THE DRY-VENTED FIXTURE DRAIN CONNECTION |
| | |
| | 2- REVISE THE DRAIN PIPE SIZE FOR ALL LAVATORIES AND |
| | KITCHEN SINKS SHOWN IN THE RISER DIAGRAM TO COMPLY WITH |
| | TABLE P3201.7 FBC-RESIDENTIAL. |
| | |
| | RESPONSE: SECOND REJECTION. ENGINEER WILL BE CHARGED 4 |
| | TIMES THE PLAN REVIEW IF COMMENT IS NOT ADDRESSED ON |
| | NEXT SUBMITTAL. REVISED PLUMBING RISER DIAGRAM 1 STILL |
| | DOESN'T COMPLY. REVISE AS REQUIRED. |
| | |
| | ARCHITECTS-ENGINEERS |
| | FLORIDA STATUTE 553.80(2)(B): |
| | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS' |
| | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN |
| | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING |
| | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS |
| | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO |
| | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY |
| | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, |
| | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, |
| | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, |
| | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER |
| | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING |
| | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL |
| | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH |
| | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, |
| | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE |
| | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. |
| | |
| | |
| | |
| | ****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. SUBMIT OLD DRAWINGS FOR REFERENCE OF ALREADY |
| | REVIEWED DRAWINGS. DON'T STAPLE OLD DRAWINGS TO PLANS. |
| | |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |
| | |
| | |