| Plan Review Notes For Permit 18020950 |
| Permit Number |
18020950 |
|
| Review Stop |
M |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-03-05 12:42:02 | 1ST REVIEW FBC-2014 MECHANICAL | | | REVISION #18020950 | | | MASTER #17060275 | | | 3/5/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) IN ORDER TO HELP EXPEDITE THE REVIEW PLEASE PROVIDE | | | A NARRATIVE FROM THE DESIGN PROFESSIONAL THAT ITEMIZES | | | AND EXPALINS WHAT CHANGES ARE VEING MADE TO THE | | | APPROVED DRAWINGS. | | | | | | 2) SHEET M1.2 : CU-2 MUST BE INSTALLED A MINIMUM OF 8' | | | ABOVE THE FINISHED FLOOR OF THE PARKING GARAGE UNLESS | | | PROTECTED FROM MOTOR VEHICLE IMPACT- SECTION 404.6. | | | | | | 3) M0.2: CHANGES HAVBE BEEN MADE TO THE AC SYSTEMS THAT | | | REQUIRE REVISED AC AND ENERGY CALCULATIONS. PLEASE | | | PROVIDE THE REVIED CALCULATIONS. | | | | | | THE MECHANICAL REVIEW IS STOPPED AT THIS TIME PENDING | | | RESUBMITTAL OF CORRECTED PLANS, REVISED CALCULATIONS, | | | AND THE REQUESTED REVISION NARRATIVE, | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|