| Date |
Text |
| 2018-03-02 13:04:53 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHT.A3.0.2 DETAIL #7 THE REAR WALL GRAB BAR SHALL BE |
| | 36 INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE |
| | OF THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND |
| | 24 INCHES MINIMUM ON THE OTHER SIDE. PER FBC ACC |
| | 604.5.2 |
| | |
| | 2. SHT.A3.0.2 DETAIL #8 SHOWS A SHOWER SEAT PLEASE SHOW |
| | ON DETAIL #6 IT SHALL COMPLY WITH FBC ACC 608.5.1 , |
| | 608.3.2 |
| | |
| | 3. SHT.A3.0.2 DETAIL #3 THE SIDE WALL GRAB BAR SHALL BE |
| | 42 INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM |
| | THE REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE |
| | REAR WALL. |
| | |
| | 4. SHT.A3.0.2 DETAIL #6 SHOW CLEAR FLOOR SPACE FOR |
| | LAVATORY. PER FBC ACC 606.2 |
| | |
| | 5. PLEASE SHOE CODE COMPLIANCE FOR FBC ACC 608.5.2 |
| | STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS. |
| | IN STANDARD ROLL-IN TYPE SHOWER COMPARTMENTS, THE |
| | CONTROLS, FAUCETS, AND SHOWER SPRAY UNIT SHALL BE |
| | LOCATED ABOVE THE GRAB BAR, BUT NO HIGHER THAN 48 |
| | INCHES ABOVE THE SHOWER FLOOR. WHERE A SEAT IS |
| | PROVIDED, THE CONTROLS, FAUCETS, AND SHOWER SPRAY UNIT |
| | SHALL BE INSTALLED ON THE BACK WALL ADJACENT TO THE |
| | SEAT WALL AND SHALL BE LOCATED 27 INCHES MAXIMUM FROM |
| | THE SEAT WALL. |
| | |
| | 6. PLEASE PROVIDE A WATER AND SANITARY ISOMETRIC |
| | DRAWING. PER WPB AMEND TO FBC 107.2.1. |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |