| 2018-03-16 16:46:14 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. PROVIDE BATHROOM DIMENSIONS TO SHOW COMPLIANCE WITH |
| | FBC RES |
| | |
| | P2708.1 GENERAL.SHOWER COMPARTMENTS SHALL HAVE NOT LESS |
| | THAN 900 SQUARE INCHES (0.6 M2) OF INTERIOR |
| | CROSS-SECTIONAL AREA. SHOWER COMPARTMENTS SHALL BE NOT |
| | LESS THAN 30 INCHES (762 MM) IN MINIMUM DIMENSION |
| | MEASURED FROM THE FINISHED INTERIOR DIMENSION OF THE |
| | SHOWER COMPARTMENT, EXCLUSIVE OF FIXTURE VALVES, SHOWER |
| | HEADS, SOAP DISHES, AND SAFETY GRAB BARS OR RAILS. THE |
| | MINIMUM REQUIRED AREA AND DIMENSION SHALL BE MEASURED |
| | FROM THE FINISHED INTERIOR DIMENSION AT A HEIGHT EQUAL |
| | TO THE TOP OF THE THRESHOLD AND AT A POINT TANGENT TO |
| | ITS CENTERLINE AND SHALL BE CONTINUED TO A HEIGHT OF |
| | NOT LESS THAN 70 INCHES (1778 MM) ABOVE THE SHOWER |
| | DRAIN OUTLET. HINGED SHOWER DOORS SHALL OPEN OUTWARD. |
| | THE WALL AREA ABOVE BUILT-IN TUBS HAVING INSTALLED |
| | SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE |
| | CONSTRUCTED IN ACCORDANCE WITH SECTION R702.4. SUCH |
| | WALLS SHALL FORM A WATER-TIGHT JOINT WITH EACH OTHER |
| | AND WITH EITHER THE TUB, RECEPTOR OR SHOWER FLOOR. |
| | |
| | |
| | P2705.1 (5) .WATER CLOSETS, LAVATORIES AND BIDETS. A |
| | WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET CLOSER |
| | THAN 15 INCHES (381 MM) FROM ITS CENTER TO ANY SIDE |
| | WALL, PARTITION OR VANITY OR CLOSER THAN 30 INCHES (762 |
| | MM) CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE |
| | SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES (533 |
| | MM) IN FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO |
| | ANY WALL, FIXTURE OR DOOR. |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |