| Date |
Text |
| 2018-02-28 11:37:34 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. SHT. S-1 SHOWS THE EXISTING RESTROOM TO BE ENLARGED |
| | THE MEP SHEETS DO NOT SHOW THE HE ENLARGED BATHROOM |
| | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 |
| | |
| | 2. THE PLAN IS REFERENCING 2014 FBC WHICH STARTING JAN. |
| | 1 CHANGED TO THE CURRENT CODE OF FBC 2017 PLEASE CHANGE |
| | ALL CODE LISTINGS TO REFLECT THE CURRENT CODE CYCLE OF |
| | 2017. |
| | |
| | 3. AS THIS IS A CHANGE OF OCCUPANCY THE EXPANDED |
| | BATHROOM WILL HAVE TO COMPLY WITH FBC EXISTING 1006.1 |
| | |
| | 4. THE EXPANDED BATHROOM SHALLL COMPLY WITH FBC ACC CH |
| | 6 PLEASE PROVIDE THE FOLLOWING DIMENSIONS AND SHOW |
| | CLEAR FLOOR SPACES. PER WPB AMEND TO FBC 107.2.1 |
| | |
| | A) 604.2 LOCATION. |
| | THE WATER CLOSET SHALL BE POSITIONED WITH A WALL OR |
| | PARTITION TO THE REAR AND TO ONE SIDE. THE CENTERLINE |
| | OF THE WATER CLOSET SHALL BE 16 INCHES (405 MM) MINIMUM |
| | TO 18 INCHES (455 MM) MAXIMUM FROM THE SIDE WALL OR |
| | PARTITION, EXCEPT THAT THE WATER CLOSET SHALL BE 17 |
| | INCHES (430 MM) MINIMUM AND 19 INCHES (485 MM) MAXIMUM |
| | FROM THE SIDE WALL OR PARTITION IN THE AMBULATORY |
| | ACCESSIBLE TOILET COMPARTMENT SPECIFIED IN 604.8.2. |
| | WATER CLOSETS SHALL BE ARRANGED FOR A LEFT-HAND OR |
| | RIGHT-HAND APPROACH. |
| | |
| | B) 604.3.1 SIZE.CLEARANCE AROUND A WATER CLOSET SHALL |
| | BE 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE |
| | SIDE WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR |
| | FROM THE REAR WALL. |
| | |
| | C) 604.4 SEATS.THE SEAT HEIGHT OF A WATER CLOSET ABOVE |
| | THE FINISH FLOOR SHALL BE 17 INCHES MINIMUM AND 19 |
| | INCHES MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS |
| | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. |
| | |
| | D) 604.5.1 SIDE WALL.THE SIDE WALL GRAB BAR SHALL BE 42 |
| | INCHES LONG MINIMUM, LOCATED 12 INCHES MAXIMUM FROM THE |
| | REAR WALL AND EXTENDING 54 INCHES MINIMUM FROM THE REAR |
| | WALL. |
| | |
| | E) 604.5.2 REAR WALL.THE REAR WALL GRAB BAR SHALL BE 36 |
| | INCHES LONG MINIMUM AND EXTEND FROM THE CENTERLINE OF |
| | THE WATER CLOSET 12 INCHES MINIMUM ON ONE SIDE AND 24 |
| | INCHES MINIMUM ON THE OTHER SIDE. |
| | |
| | F) 604.7 DISPENSERS. TOILET PAPER DISPENSERS SHALL |
| | COMPLY WITH 309.4 AND SHALL BE 7 INCHES MINIMUM AND 9 |
| | INCHES MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO |
| | THE CENTERLINE OF THE DISPENSER. THE OUTLET OF THE |
| | DISPENSER SHALL BE 15 INCHES MINIMUM AND 48 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR. |
| | |
| | G) 603.3 MIRRORS.MIRRORS LOCATED ABOVE LAVATORIES OR |
| | COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF |
| | THE REFLECTING SURFACE 40 INCHES (1015 MM) MAXIMUM |
| | ABOVE THE FINISH FLOOR OR GROUND. MIRRORS NOT LOCATED |
| | ABOVE LAVATORIES OR COUNTERTOPS SHALL BE INSTALLED WITH |
| | THE BOTTOM EDGE OF THE REFLECTING SURFACE 35 INCHES |
| | (890 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | H) 609.4 POSITION OF GRAB BARS.GRAB BARS SHALL BE |
| | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM |
| | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED |
| | TO THE TOP OF THE GRIPPING SURFACE, |
| | |
| | 5. THE 3 COMPARTMENT SINK SHAL BE INDIRECT WASTE. PER |
| | FBC PL 802.1.1 |
| | |
| | 6. THE GREASE INTERCEPTOR AND HAND SINK SHALL CONNECT |
| | TO THE BUILDING DRAIN DOWN STREAM OF THE BATHROOM GROUP |
| | WET VENT PER FBC PL 912.1 |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |