2018-04-09 10:25:04PLUMBING PROVISO:
  
 1. PROVIDE TEMPERED WATER AT THE LAVATORY.
 FBC PL 416.5 TEMPERED WATER SHALL BE DELIVERED FROM
 LAVATORIES AND GROUP WASH FIXTURES LOCATED IN PUBLIC
 TOILET FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND
 VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN
 APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT
 CONFORMS TO ASSE 1070 OR CSA B125.3.
 FBC PL 607.1 HOT OR TEMPERED WATER WHERE REQUIRED.
 IN NONRESIDENTIAL OCCUPANCIES, HOT WATER SHALL BE
 SUPPLIED FOR CULINARY PURPOSES, CLEANSING, LAUNDRY OR
 BUILDING MAINTENANCE PURPOSES. IN NONRESIDENTIAL
 OCCUPANCIES, HOT WATER OR TEMPERED WATER SHALL BE
 SUPPLIED FOR BATHING AND WASHING PURPOSES.
 1. FBC ACC 604.7
 TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT
 OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE
 DISPENSER.
 2. FBC ACC 609.4 GRAB BARS SHALL BE INSTALLED IN A
 HORIZONTAL POSITION, 33 INCHES MINIMUM AND 36 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR MEASURED TO THE TOP OF
 THE GRIPPING SURFACE
  