2018-02-16 14:43:102017 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 18020262
 ADD: 7437 RIVERWALK CIRCLE
 CONT: EVERKLEEN CONSTRUCTION
 TEL: 561-818-7082
 E-MAIL: [email protected]
  
 2017 FLORIDA BUILDING CODE W 2017 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2017 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. FEB. 16/ 2018
 ACTION: DENIED
  
 1) DISCREPANCY IN OCCUPANT LOAD. THE COVERSHEET STATES
 THERE IS 94 SEATING CAPACITY. SHEET 1.3A INDICATES A
 SEATING COUNT OF NON-FIXED SEATING 53 AND BENCH SEATING
 OF 22 TOTALING 75 SEATS. WHEN TAKING A COUNT OF ALL
 SEATING INCLUDING ACCESSIBLE SEATING THE COUNT IS 97
 SEATED OCCUPANTS. PLEASE ALSO SEE THE DISCREPANCY IN
 THE RETAIL CAF? TAKEN AT 30. UNDER THE 2017 FBC-B
 MERCANTILE 1ST FLOOR IS NOW TO BE TAKEN AT 60 SQ. FT./
 OCCUPANT (SEE 2017 FBC-B TABLE 1004.1.2.). THIS WILL
 DECREASE THE OCCUPANT LOAD. PLEASE PROVIDE A REVISED
 OCCUPANT LOAD COUNT ON THE COVERSHEET AS WELL AS ON
 SHEET 1.3A.
  
 2) THE COVERSHEET UNDER THE SCOPE OF WORK INDICATES
 WITH NOTE # 17 TO REMOVE A PAIR OF GLASS ALUMINUM DOORS
 AND REPLACE WITH A NEW SINGLE IMPACT UNIT TO WITHSTAND
 170 PSF. NOTE # 18 STATES TO BLOCK IN ? OF THE DOOR
 OPENING. SHEETS 1.1A, 1.21A NOR 1.3.A SHOW THE REMOVAL
 OF DOORS, NOR THE INSTALLATION OF A NEW SINGLE DOOR AND
 ? OF THE OLD OPENING BLOCKED IN. THERE IS NO DETAIL
 PROVIDING HOW THE NEW WALL SECTION WOULD BE ANCHORED
 INTO THE MWFRS (MAIN WIND FORCE RESISTING SYSTEM)
 CONTENTIOUS LOADING TO THE FOUNDATION. 107.2.1.3
 ADDITIONAL INFORMATION IS REQUIRED. FBC-B 1609.6.3/
 1609.6.4.
  
 3) MISSING THE WIND DESIGN CRITERIA. 2014 FBC-B
 1603.1.4 WIND DESIGN DATA.
 THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL
 BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE
 DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE
 STRUCTURE:
  
 3.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST),
 MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS
 DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1.
  
 3.2. RISK CATEGORY.
  
 3.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE
 THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2.
 HEIGHT AND EXPOSURE.
  
 3.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT.
  
 3.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR
 COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY
 DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL
 RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF.
 TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT &
 EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE
 BUILDING.
 1609.3.1 WIND SPEED CONVERSION VULT TO VASD.
  
 4) 2017 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS ,MULLIONS, SIDELIGHTS & TRANSOMS
  
 5) W. P. B. 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS
 WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF
 RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL.
 FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR
 SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS,
 SHOP DRAWINGS ETC..
 6) PLEASE SHOW COMPLIANCE WITH ACCESSIBLE DINING
 TABLES;
 6)(A) 902.2 CLEAR FLOOR OR GROUND SPACE. A CLEAR FLOOR
 SPACE COMPLYING WITH 305 POSITIONED FOR A FORWARD
 APPROACH SHALL BE PROVIDED. KNEE AND TOE CLEARANCE
 COMPLYING WITH 306 SHALL BE PROVIDED.
  
 6)(B) 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 7) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT
 FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF
 PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR
 REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE
 OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST
 PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE
 STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL
 (561)233-5025 FOR MORE INFORMATION.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION &
 REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER