| Plan Review Notes For Permit 18020036 |
| Permit Number |
18020036 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-02-07 06:40:37 | DENIED | | | | | | PLUMBING REPAIR TUNNEL WORK | | | | | | A CLEAR AND LEGIBLE SANITARY RISER DIAGRAM SHALL BE | | | SUBMITTED SHOWING ALL PIPE SIZES, CONNECTION POINTS TO | | | EXISTING PIPING, HOW THE NEW PIPE WILL BE SUPPORTED, | | | THE TYPE OF ADAPTERS USED FOR THE CONNECTIONS TO | | | EXISTING PIPE, AND THE LOCATIONS OF REQUIRED CLEANOUTS. | | | DETAILS AND BACKFILLING PROCEDURES SHALL BE SUBMITTED | | | THAT CLEARLY SHOW HOW THE STRUCTURAL INTEGRITY OF THE | | | CONCRETE SLAB WILL BE MAINTAINED DURING EXCAVATION AND | | | BACKFILLING. STRUCTURAL FOAM IS NOT PERMITTED BELOW | | | GROUND PER THE 2017 FLORIDA BUILDING CODE, RESIDENTIAL, | | | SECTION 318.8 AND THE 2017 FLORIDA BUILDING CODE, | | | BUILDING, SECTION 2603.9. | | | A SIGNED AND SEALED LETTER FROM AN ENGINEER MAY BE | | | REQUIRED TO CERTIFY THE STRUCTURAL INTEGRITY OF THE | | | EXISTING SLAB. | | | THE BACKFILL UNDER THE SLAB SHALL BE TREATED FOR | | | TERMITES PER THE 2017 FBC B SEC.1816.1 OR 2017 FBC R | | | SEC. 318.1. A TERMITE CERTIFICATE SHALL BE ONSITE FOR | | | FINAL INSPECTION. | | | | | | LUIS A. CRESPO | | | PLUMBING INSPECTOR / | | | PLUMBING PLAN REVIEW | | | [email protected] | | | 561-805-6720 | | | |
|