Plan Review Notes
Plan Review Notes For Permit 18011074
Permit Number 18011074
Review Stop B
Sequence Number 1
Notes
Date Text
2018-01-30 06:17:232014 FBC- BUILDING PLAN REVIEW
 W.P.B. REVISION 18011074
 W. P. B. PERMIT: 17040694
 ADD: 3000 N. AUSTRALIAN AVE.
 CONT: DOSDOURIAN ENTERPRISES
 TEL: 561-644-4704
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. JAN. 30/ 2018
 ACTION: PASSED
  
 804.4.1 TEST REQUIREMENT.
 IN ALL OCCUPANCIES, INTERIOR FLOOR COVERING MATERIALS
 SHALL COMPLY WITH THE REQUIREMENTS OF THE DOC FF-1
 ?PILL TEST? (CPSC 16 CFR PART 1630) OR WITH ASTM D
 2859.
  
 804.4.2 MINIMUM CRITICAL RADIANT FLUX.
 IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR
 COVERING MATERIALS IN ENCLOSURES FOR STAIRWAYS AND
 RAMPS, EXIT PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES
 NOT SEPARATED FROM CORRIDORS BY PARTITIONS EXTENDING
 FROM THE FLOOR TO THE UNDERSIDE OF THE CEILING SHALL
 WITHSTAND A MINIMUM CRITICAL RADIANT FLUX. THE MINIMUM
 CRITICAL RADIANT FLUX SHALL NOT BE LESS THAN CLASS I IN
 GROUPS I-1, I-2 AND I-3 AND NOT LESS THAN CLASS II IN
 GROUPS A, B, E, H, I- 4, M, R-1, R-2 AND S.
  
 EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH
 AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE
 PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE
 REQUIRED, AND MATERIALS COMPLYING WITH DOC FF-1 ?PILL
 TEST? (CPSC 16 CFR PART 1630) OR WITH ASTM D 2859 ARE
 PERMITTED IN ANY AREA WHERE CLASS II MATERIALS ARE
 REQUIRED.
  
 PRODUCT: PATCRAFT
 COLLECTION: SPEAK YOUR LANGUAGE
 STYLE 10239
 PRODUCT TYPE MODULAR CONSTRUCTION MULTI-LEVEL PATTERN
 LOOP
 FIBER STYLE: ECO SOLUTION Q NYLON
 METHANAMINE PILL TEST PASSES (DOCFF-1-70) RADIANT PANEL
 CLASS I
  
 804.4.2 MINIMUM CRITICAL RADIANT FLUX.
 IN ALL OCCUPANCIES, INTERIOR FLOOR FINISH AND FLOOR
 COVERING MATERIALS IN ENCLOSURES FOR STAIRWAYS AND
 RAMPS, EXIT PASSAGEWAYS, CORRIDORS AND ROOMS OR SPACES
 NOT SEPARATED FROM CORRIDORS BY PARTITIONS EXTENDING
 FROM THE FLOOR TO THE UNDERSIDE OF THE CEILING SHALL
 WITHSTAND A MINIMUM CRITICAL RADIANT FLUX. THE MINIMUM
 CRITICAL RADIANT FLUX SHALL NOT BE LESS THAN CLASS I IN
 GROUPS I-1, I-2 AND I-3 AND NOT LESS THAN CLASS II IN
 GROUPS A, B, E, H, I- 4, M, R-1, R-2 AND S.
  
 EXCEPTION: WHERE A BUILDING IS EQUIPPED THROUGHOUT WITH
 AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH
 SECTION 903.3.1.1 OR 903.3.1.2, CLASS II MATERIALS ARE
 PERMITTED IN ANY AREA WHERE CLASS I MATERIALS ARE
 REQUIRED, AND MATERIALS COMPLYING WITH DOC FF-1 ?PILL
 TEST? (CPSC 16 CFR PART 1630) OR WITH ASTM D 2859 ARE
 PERMITTED IN ANY AREA WHERE CLASS II MATERIALS ARE
 REQUIRED.
  
  
  