| Date |
Text |
| 2018-01-31 09:39:21 | BUILDING PLAN REVIEW |
| | 2017 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. VALUE APPEARS LOW. THE ICC VALUATION DATA REV. 08/17 |
| | STATES A UTILITY STRUCTURE TYPE IIB SHALL BE VALUED AT |
| | 67.61 PER SQ. FT. PROPOSED STRUCTURE IS 648 SQ. FT. |
| | VALUE WILL BE ADJUSTED TO 43,811.28. |
| | 2. NOTE: STORAGE SHEDS THAT ARE NOT DESIGNED FOR HUMAN |
| | HABITATION AND THAT HAVE A FLOOR AREA OF 720 SQUARE |
| | FEET (67 M2) OR LESS ARE NOT REQUIRED TO COMPLY WITH |
| | THE MANDATORY WINDBORNE DEBRIS IMPACT STANDARDS OF THIS |
| | CODE. |
| | CONTRACT REQUIRES IMPACT RATED DOORS. PRODUCT APPROVALS |
| | SUBMITTED FOR SWINGING DOOR AND OHD ARE FOR NON-IMPACT |
| | RATED ASSEMBLIES. PROVIDE PRODUCT APPROVALS FOR IMPACT |
| | RATED DOORS. |
| | 3. PROVIDE PRODUCT APPROVALS FOR EXTERIOR CLADDING. |
| | 4. PROVIDE ROOF FRAMING PLAN. |
| | 5. REF. PG. 4 OF 4 OF THE SUBMITTED DESIGN. 18 GUAGE |
| | ROOF FURRING CHANNELS DO NOT MEET THE REQUIREMENTS OF |
| | THE 16 GUAGE SUPPORTS REQUIRED BY THE ROOF DECK PRODUCT |
| | APPROVAL. |
| | 6. REF. PG 4 OF 4 OF THE SUBMITTED DESIGN. THERE ARE |
| | MULTIPLE ARES REQUIRING WELDED CONNECTIONS. PROVIDE |
| | WELDER CERTIFICATION IN FIELD AT TIME OF INSPECTION. |
| | 7. DESIGNER TO REVIEW AND APPROVE IN WRITING ALL |
| | PRODUCT APPROVALS. PLEASE IDENTIFY WHICH MODEL OF DOOR |
| | IS TO BE INSTALLED. |
| | |
| | CITY OF WPB CHPT. 1 - VALUE |
| | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF |
| | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE |
| | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, |
| | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS |
| | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE |
| | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION |
| | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT |
| | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, |
| | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, |
| | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION |
| | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), |
| | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. |
| | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE |
| | BUILDING OFFICIAL. |
| | |
| | 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. |
| | CONSTRUCTION DOCUMENTS SHALL BE |
| | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. |
| | CONSTRUCTION DOCUMENTS SHALL BE OF SUFFICIENT CLARITY |
| | TO INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | SPECIFICALLY, PROVIDE ROOFING, SIDING AND DOOR |
| | SUBMITTALS. |
| | |
| | |
| | |
| | |