| Notes |
| Date |
Text |
| 2018-01-24 14:40:54 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) THE LAUNDRY/CLSET ROOM DORR, # 16, SWING OUT INTO | | | THE EXIT TRAVEL PATH. CHANGE TO IN-SWING OR ADD A DOOR | | | CLOSER. | | | | | | PER NFPA 101, CHAPTER 7 MEANS OF EGRESS : | | | | | | 7.2.1.4.3* DOOR LEAF ENCROACHMENT. | | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE | | | REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY, | | | OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF THE FOLLOWING | | | CONDITIONS ARE MET: | | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | | EXISTING BUILDING. | | | (2) THE DOOR OPENING MEETS THE REQUIREMENT OF | | | 7.2.1.4.3.2. | | | 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS | | | OF EGRESS SHALL NOT PROJECT MORE THAN 7 IN. (180 MM) | | | INTO THE REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A | | | PASSAGEWAY, OR A LANDING, UNLESS THE DOOR LEAF IS | | | EQUIPPED WITH AN APPROVED SELF-CLOSING DEVICE AND IS | | | NOT REQUIRED BY THE PROVISIONS OF 7.2.1.4.2 TO SWING IN | | | THE DIRECTION OF EGRESS TRAVEL. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|