2018-01-24 14:40:54THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE LAUNDRY/CLSET ROOM DORR, # 16, SWING OUT INTO
 THE EXIT TRAVEL PATH. CHANGE TO IN-SWING OR ADD A DOOR
 CLOSER.
  
 PER NFPA 101, CHAPTER 7 MEANS OF EGRESS :
  
 7.2.1.4.3* DOOR LEAF ENCROACHMENT.
 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL LEAVE NOT LESS THAN ONE-HALF OF THE
 REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A PASSAGEWAY,
 OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF THE FOLLOWING
 CONDITIONS ARE MET:
 (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN
 EXISTING BUILDING.
 (2) THE DOOR OPENING MEETS THE REQUIREMENT OF
 7.2.1.4.3.2.
 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS
 OF EGRESS SHALL NOT PROJECT MORE THAN 7 IN. (180 MM)
 INTO THE REQUIRED WIDTH OF AN AISLE, A CORRIDOR, A
 PASSAGEWAY, OR A LANDING, UNLESS THE DOOR LEAF IS
 EQUIPPED WITH AN APPROVED SELF-CLOSING DEVICE AND IS
 NOT REQUIRED BY THE PROVISIONS OF 7.2.1.4.2 TO SWING IN
 THE DIRECTION OF EGRESS TRAVEL.
  
  
 PETER LEDUC
 FIRE MARSHAL