| Plan Review Notes For Permit 18010592 |
| Permit Number |
18010592 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2018-02-14 07:20:41 | 1ST REVIEW: FBC 2017 6TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE WASHING MACHINE BOX IS NOT VENTED. PER FBC RES | | | P3101.2.1 | | | | | | 2. THE BAR SINK SHALL CONNECT TO THE BRANCH DRAIN OR | | | BUILDING DRAIN DOWN STREAM OF THE BATHROOM GROUP IT CAN | | | NOT CONNECT TO THE HORIZONTAL WET DRAIN OF THE BATHROOM | | | GROUP. P3108.1 | | | | | | 3. THE AAV ON THE BATHROOM #2 SHOWER SHALL BE | | | ACCESSIBLE. FBC RES P3114.5 ACCESS AND VENTILATION. | | | ACCESS SHALL BE PROVIDED TO AIR ADMITTANCE VALVES. SUCH | | | VALVES SHALL BE INSTALLED IN A LOCATION THAT ALLOWS AIR | | | TO ENTER THE VALVE. | | | | | | 4. BATHROOM #2 IS LABELED AS LAUNDRY-ON THE ISOMETRIC | | | DRAWING PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. PROVIDE THE SQFT ON THE ROOF DRAINS. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|