| Date |
Text |
| 2018-02-28 15:03:03 | 1ST REVIEW: FBC 2017 6TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | 1. PROVIDE DIMENSIONS FOR SHOWER SHALL COMPLY WITH FBC |
| | ACC |
| | A) 608.2.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. |
| | ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS SHALL BE 36 |
| | INCHES (915 MM) WIDE AND 60 INCHES (1525 MM) DEEP |
| | MINIMUM CLEAR INSIDE DIMENSIONS MEASURED AT CENTER |
| | POINTS OF OPPOSING SIDES.A 36 INCH (915 MM) WIDE |
| | MINIMUM ENTRY SHALL BE PROVIDED AT ONE END OF THE LONG |
| | SIDE OF THE COMPARTMENT. |
| | B) 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. |
| | IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, |
| | FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON |
| | THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) |
| | MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE |
| | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL |
| | 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE |
| | SEAT TOWARD THE SHOWER OPENING. |
| | C) 608.3.3 ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS. |
| | IN ALTERNATE ROLL-IN TYPE SHOWER COMPARTMENTS, GRAB |
| | BARS SHALL BE PROVIDED ON THE BACK WALL AND THE SIDE |
| | WALL FARTHEST FROM THE COMPARTMENT ENTRY. GRAB BARS |
| | SHALL NOT BE PROVIDED ABOVE THE SEAT. GRAB BARS SHALL |
| | BE INSTALLED 6 INCHES (150 MM) MAXIMUM FROM ADJACENT |
| | WALLS. |
| | |
| | 2. THE BREAK ROOM SINK SHALL COMPLY WITH FBC ACC |
| | 606.1 GENERAL. |
| | LAVATORIES AND SINKS SHALL COMPLY WITH 606. |
| | A)606.2 CLEAR FLOOR SPACE. |
| | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR |
| | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE |
| | COMPLYING WITH 306 SHALL BE PROVIDED. |
| | B)606.3 HEIGHT. |
| | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT |
| | OF THE HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES |
| | (865 MM) MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 3. THE SIDE WALL GRAB BAR OF THE TOILET SHALL COMPLY |
| | WITH FBC ACC 604.5.1 SIDE WALL. |
| | THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) |
| | LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM |
| | THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM |
| | FROM THE REAR WALL. |
| | |
| | 4. SHOW COMPLIANCE WITH FBC ACC 602 FOR THE WATER |
| | FOUNTAIN. 602 |
| | DRINKING FOUNTAINS SHALL COMPLY WITH 307 AND 602. |
| | A) 602.2 CLEAR FLOOR SPACE. |
| | UNITS SHALL HAVE A CLEAR FLOOR OR GROUND SPACE |
| | COMPLYING WITH 305 POSITIONED FOR A FORWARD APPROACH |
| | AND CENTERED ON THE UNIT. KNEE AND TOE CLEARANCE |
| | COMPLYING WITH 306 SHALL BE PROVIDED. |
| | B) 602.4 SPOUT HEIGHT. |
| | SPOUT OUTLETS SHALL BE 36 INCHES (915 MM) MAXIMUM ABOVE |
| | THE FINISH FLOOR OR GROUND. |
| | C) 602.7 DRINKING FOUNTAINS FOR STANDING PERSONS. |
| | SPOUT OUTLETS OF DRINKING FOUNTAINS FOR STANDING |
| | PERSONS SHALL BE 38 INCHES (965 MM) MINIMUM AND 43 |
| | INCHES (1090 MM) MAXIMUM ABOVE THE FINISH FLOOR OR |
| | GROUND. |
| | |
| | 5. TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES |
| | AND GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET |
| | FACILITIES PROVIDED FOR CUSTOMERS, PATRONS AND |
| | VISITORS. TEMPERED WATER SHALL BE DELIVERED THROUGH AN |
| | APPROVED WATER-TEMPERATURE LIMITING DEVICE THAT |
| | CONFORMS TO ASSE 1070 OR CSA B125.3. PER FBC PL 416.5 |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |