| 2018-01-29 08:25:29 | PROVISO - THE TEMPORARY TENTS REQUIRE BUILDING REVIEW |
| | PER FBC BUILDING 3103 |
| | |
| | SECTION 3103 |
| | TEMPORARY STRUCTURES |
| | 3103.1 GENERAL. |
| | THE PROVISIONS OF SECTIONS 3103.1 THROUGH 3103.4 SHALL |
| | APPLY TO STRUCTURES ERECTED FOR A PERIOD OF LESS THAN |
| | 180 DAYS. TENTS AND OTHER MEMBRANE STRUCTURES ERECTED |
| | FOR A PERIOD OF LESS THAN 180 DAYS SHALL COMPLY WITH |
| | THE FLORIDA FIRE PREVENTION CODE. THOSE ERECTED FOR A |
| | LONGER PERIOD OF TIME SHALL COMPLY WITH APPLICABLE |
| | SECTIONS OF THIS CODE. |
| | 3103.1.1 CONFORMANCE. |
| | TEMPORARY STRUCTURES AND USES SHALL CONFORM TO THE |
| | STRUCTURAL STRENGTH, FIRE SAFETY, MEANS OF EGRESS, |
| | ACCESSIBILITY, LIGHT, VENTILATION AND SANITARY |
| | REQUIREMENTS OF THIS CODE AS NECESSARY TO ENSURE PUBLIC |
| | HEALTH, SAFETY AND GENERAL WELFARE. |
| | 3103.1.2 PERMIT REQUIRED. |
| | TEMPORARY STRUCTURES THAT COVER AN AREA GREATER THAN |
| | 120 SQUARE FEET (11.16 M2), INCLUDING CONNECTING AREAS |
| | OR SPACES WITH A COMMON MEANS OF EGRESS OR ENTRANCE |
| | THAT ARE USED OR INTENDED TO BE USED FOR THE GATHERING |
| | TOGETHER OF 10 OR MORE PERSONS, SHALL NOT BE ERECTED, |
| | OPERATED OR MAINTAINED FOR ANY PURPOSE WITHOUT |
| | OBTAINING A PERMIT FROM THE BUILDING OFFICIAL. |
| | 3103.2 CONSTRUCTION DOCUMENTS. |
| | A PERMIT APPLICATION AND CONSTRUCTION DOCUMENTS SHALL |
| | BE SUBMITTED FOR EACH INSTALLATION OF A TEMPORARY |
| | STRUCTURE. THE CONSTRUCTION DOCUMENTS SHALL INCLUDE A |
| | SITE PLAN INDICATING THE LOCATION OF THE TEMPORARY |
| | STRUCTURE AND INFORMATION DELINEATING THE MEANS OF |
| | EGRESS AND THE OCCUPANT LOAD. |
| | 3103.3 LOCATION. |
| | TEMPORARY STRUCTURES SHALL BE LOCATED IN ACCORDANCE |
| | WITH THE REQUIREMENTS OF TABLE 602 BASED ON THE |
| | FIRE-RESISTANCE RATING OF THE EXTERIOR WALLS FOR THE |
| | PROPOSED TYPE OF CONSTRUCTION. |
| | 3103.4 MEANS OF EGRESS. |
| | TEMPORARY STRUCTURES SHALL CONFORM TO THE MEANS OF |
| | EGRESS REQUIREMENTS OF CHAPTER 10 AND SHALL HAVE AN |
| | EXIT ACCESS TRAVEL DISTANCE OF 100 FEET (30 480 MM) OR |
| | LESS. |