| 2018-01-30 16:02:18 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 2ND REVIEW: FBC SIXTH EDITION (2017) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) ACCORDING TO THE FBC EXISTING BUILDING, THIS PROJECT |
| | IS CONSIDERED A LEVEL 3 ALTERATION. SPECIFY THE LEVEL |
| | OF ALTERATION ON THE PLANS. FBC EXISTING BUILDING |
| | SECTION 505 |
| | |
| | 2) THE PROPOSED FLOOR PLANS THAT WERE SUBMITTED SHOW |
| | CHANGES TO THE EXTERIOR DOORS AND WINDOWS OF THE |
| | STRUCTURE. PROVIDE A COMPLETE SCOPE OF WORK ON THE |
| | PLANS. FBC 107.2.1 |
| | |
| | 3) PROVIDE A DOOR SCHEDULE WITH SIZES ON THE PLANS. FBC |
| | 107.2.1 |
| | |
| | 4) PROVIDE A DETAIL SHOWING HOW THE OPENINGS IN THE |
| | EXTERIOR WALLS WILL BE INFILL-ED. INCLUDING INSULATION, |
| | INTERIOR AND EXTERIOR WALL COVERINGS. FBC-R702 AND R703 |
| | |
| | 5) SHOW COMPLIANCE WITH FBC-R310.1 EMERGENCY ESCAPE AND |
| | RESCUE REQUIRED. BASEMENTS, HABITABLE ATTICS AND EVERY |
| | SLEEPING ROOM SHALL HAVE AT LEAST ONE OPERABLE |
| | EMERGENCY ESCAPE AND RESCUE OPENING. IDENTIFY THE |
| | EGRESS WINDOWS FOR THE SECOND FLOOR BEDROOMS ON THE |
| | PLANS. FBC 107.2.1 |
| | |
| | 6) FBC-R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS. |
| | WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A |
| | PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE |
| | ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL |
| | DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS |
| | LOCATED AS REQUIRED FOR NEW DWELLINGS. |
| | |
| | 7) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH |
| | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS |
| | AND MAXIMUM DESIGN PRESSURES FOR THE EXTERIOR DOORS AND |
| | WINDOWS. PRODUCT APPROVALS HAVE NOT BEEN APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 8) THE PROPOSED ELEVATIONS ON A-4 SHOW A LARGER LAUNDRY |
| | ROOM AT THE REAR THAN IS SHOWN ON THE EXISTING |
| | ELEVATIONS ON SHEET A-3. THE LAUNDRY ROOM IS SHOWN WITH |
| | A FLAT ROOF ON THE EXISTING ELEVATIONS AND WITH A SHED |
| | ROOF ON THE PROPOSED. THE PROPOSED FLOOR PLANS AND |
| | ELECTICAL PLANS DO NOT SHOW THIS ROOM. NO INFORMATION |
| | IS PROVIDED FOR ADDING ON TO OR REMODELING THIS ROOM. |
| | COMPLETE DETAILS WILL BE REQUIRED FOR THIS ROOM. |
| | CLARIFY. FBC 107.1.2 |
| | |
| | 9) INTERIOR WALL DETAIL 1 ON A-2, SPECIFIES STUCCO OVER |
| | PAPER BACKED METAL LATH ON 5/8" CDX PLYWOOD SHEATHING. |
| | THIS APPEARS TO BE AN ERROR, PLEASE CORRECT. |
| | |
| | 10) PRODUCT APPROVALS WERE SUBMITTED FOR AWNING WINDOWS |
| | AND FIXED CASEMENT WINDOWS. THESE WINDOWS ARE NOT |
| | SPECIFIED IN THE WINDOW SCHEDULE. PLEASE CLARIFY. |
| | |
| | 11) DOORS #3 AND #4 ARE SHOWN ON SHEET A-4. THEY APPEAR |
| | TO BE 6 PANEL COLONIAL STYLE DOORS. THERE WERE NO |
| | PRODUCT APPROVALS SUBMITTED FOR THESE DOORS. SUBMIT |
| | PRODUCT APPROVALS PER FBC107.3.4. |
| | |
| | 12) THE PLANS REFERENCE THE FBC FIFTH EDITION (2014). |
| | THE FBC SIXTH EDITION (2017) WENT INTO EFFECT ON |
| | JANUARY 1, 2018. ALL NEW PERMITS APPLIED FOR ON OR |
| | AFTER THAT DATE ARE REQUIRED TO COMPLY WITH AND |
| | REFERENCE THE FBC SIXTH EDITION (2017). |
| | |
| | 13) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT |
| | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |