| Date |
Text |
| 2018-04-25 10:32:11 | 1ST REVIEW: FBC 2014 5TH EDITION |
| | |
| | PLUMBING COMMENTS: |
| | |
| | PREVIOUS COMMENTS NOT COMPLIED 14. ALL FIXTURES IN |
| | KITCHEN AREA SHALL DISCHARGE TO THE GREASE INCEPTOR. |
| | PER FBC PL 1003.3.1 THE HAND SINKS THE SINKS AND FLOOR |
| | SINK AT ESPRESSO MACHINE THE SINK AT THE FRONT COUNTER |
| | ALL SHALL BE ON THE GREASE WASTE THE ONLY FIXTURES THAT |
| | CAN CONNECT TO THE SANITARY IS THE BATHROOM FIXTURES |
| | AND THE SINKS AND DRAINS AT THE WAITRESS STATION WITH |
| | THE ICE AND WATER DISPENSER. THIS IS NOT ONLY A |
| | REQUIREMENT OF THE PLUMBING CODE BUT ALSO ARE UTILITIES |
| | DEPORTMENT AND WEST PALM BEACH CODE OF ORDINANCE SEC. |
| | 90-126(7) |
| | |
| | NEW COMMENTS: |
| | |
| | 1. SHT. A-400 THE MIRROR APPEARS TO BE SHOWN AT 41" TO |
| | THE BOTTOM OF THE FRAME IT BE BE SHOWN AT 40" TO THE |
| | BOTTOM OF THE REFLECTIVE SURFACE. PER FBC ACC 603.3 |
| | |
| | 2. SHT. A-400 THE GRAB BARS ARE SHOWN TO BE MEASURED TO |
| | THE CENTER OF THE GRAB BAR IT SHALL BE SHOWN MEASURED |
| | TO THE TOP OF THE GRIPPING SURFACE. IF INSTALLED AT 36" |
| | TO THE CENTER OF THE GRAB BAR IT WILL BE 3/4" TO HIGH |
| | AND NON CODE COMPLIANT. PER FBC ACC 609.4 |
| | |
| | 3. SHT. A-400 PLEASE SHOW THE TOILETPAPER DISPENSER AT |
| | 7"- 9" OFF THE FRONT OF THE TOILET. PER FBC ACC 604.7 |
| | |
| | 4. SHT. A-402 THE GRAB BAR ON THE REAR WALL DOES NOT |
| | COMPLY THE WAY IT IS SHOWN PLEASE SHOW COMPLIANCE WITH |
| | FBC ACC 604.5.2 REAR WALL. THE REAR WALL GRAB BAR SHALL |
| | BE 36 INCHES LONG MINIMUM AND EXTEND FROM THE |
| | CENTERLINE OF THE WATER CLOSET 12 INCHES MINIMUM ON ONE |
| | SIDE AND 24 INCHES MINIMUM ON THE OTHER SIDE. |
| | |
| | |
| | |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |