| 2019-01-10 18:39:00 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17121030 |
| | ADD: 200 CLEMATIS ST. / 1ST FLOOR AND MEZZANINE. |
| | CONT: CONSTRUCTION TECHNOLOGIES |
| | TEL: 954-709-1935 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE & 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | PLAN |
| | REVIEW COMMENTS |
| | 4TH REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | PLEASE COMPLY WITH: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & |
| | REPLACE ANY PAGES AS NECESSARY, COLATE PLANS INTO |
| | COMPLETE SETS. PLANS WILL NOT BE ISSUED IN PARTIAL |
| | SETS!!!!!!!!!!! |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | IT APPEARS THAT ALL OF THE ITEMS HAVE BEEN ADDRESSED |
| | EXCEPT FOR THE FOLLOWING ITEMS: |
| | |
| | 1) THE WIND DESIGN DATA AND OPENING PRESSURES FOR THE |
| | NEW EXTERIOR DOOR OPENINGS WAS NOT ADDRESSED. THIS WILL |
| | BE ADDRESSED ALONG WITH THE REQUIRED PRODUCT APPROVALS |
| | ON A SEPARATE PERMIT FOR THE INSTALLATION OF THE NEW |
| | DOORS PER ARCHITECT'S RESPONSE LETTER. FBC 1603.1.4 |
| | |
| | 2) IT HAS BEEN BROUGHT TO MY ATTENTION THAT THE RAMP AT |
| | THE EXIT EGRESS DOOR ON THE EAST SIDE OF THE BUILDING |
| | WILL NOT BE REQUIRED. THE 2004 FBC ACCESSIBILITY |
| | SECTION 207.1 STATES THAT MEANS OF EGRESS SHALL COMPLY |
| | WITH 1003.2.13 OF THE 2000 EDITION OF THE INTERNATIONAL |
| | BUILDING CODE OR SECTION 1007 OF THE 2003 IBC. THESE |
| | SECTIONS HAVE AN EXCEPTION WHICH STATES THAT AN |
| | ACCESSIBLE MEANS OF EGRESS IS NOT REQUIRED IN |
| | ALTERATIONS TO EXISTING BUILDINGS. THEREFORE, THIS DOOR |
| | IS NOT BE REQUIRED TO HAVE A RAMP. PLEASE SUBMIT |
| | REVISED DRAWINGS THAT DO NOT SHOW THE RAMP. (THE RAMP |
| | THAT IS SHOWN EXTENDS BEYOND THE PROPERTY LINE AND THE |
| | LANDING WOULD NEED TO BE 60" WIDE DUE TO THE CHANGE IN |
| | DIRECTION.) FBC ACCESSIBILITY SECTION 405.7.4 |
| | |
| | 3) THE CALCULATIONS AND DRAWINGS THAT WERE SUBMITTED |
| | FOR THE VERTICAL TYPE B GAS VENTS LOCATED ON THE |
| | BUILDINGS EXTERIOR ADDRESSED THE WIND LOADS. HOWEVER, |
| | THE GRAVITY LOAD OF THE THESE VERTICAL GAS VENT PIPES |
| | WAS NOT ADDRESSED. SPECIFY THE TYPE OF CLAMPS THAT WILL |
| | BE USED AND HOW THEY WILL SUPPORT THE WEIGHT OF THE |
| | VERTICALLY INSTALLED VENTS. FBC 107.2.1.3 |
| | |
| | 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | |
| | |
| | |
| | |