| 2018-11-05 13:37:04 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17121030 |
| | ADD: 200 CLEMATIS ST. / 1ST FLOOR AND MEZZANINE. |
| | CONT: CONSTRUCTION TECHNOLOGIES |
| | TEL: 954-709-1935 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 3RD REVIEW |
| | DATE: MON. NOV. 05/2018 |
| | ACTION: DENIED |
| | |
| | PLEASE COMPLY WITH: WHEN RESUBMITTING PLANS PLEASE |
| | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & |
| | REPLACE ANY PAGES AS NECESSARY, COLATE PLANS INTO |
| | COMPLETE SETS. PLANS WILL NOT BE ISSUED IN PARTIAL |
| | SETS!!!!!!!!!!! |
| | A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | 1) THE COVERSHEET LIST THE OF DRAWINGS INDICATES THERE |
| | ARE NO MECHANICAL, PLUMBING, ELECTRICAL, PLANS TO BE |
| | UNDER SEPARATE PERMIT. PLEASE NOTE THE SCOPE OF THE |
| | WHOLE PROJECT IS INTERRELATED WITH ALL TRADES. |
| | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC... THE ARCHITECT OF RECORD WILL NEED |
| | TO COORDINATE TRADES, AND MATERIALS. THERE HAS TO BE A |
| | PROFESSIONAL DESIGNER OVER ALL OF THE PROJECT. |
| | |
| | 1A) COMPLIED. ENGINEERING PLANS AND CALCULATIONS. |
| | |
| | |
| | 2-3) NOT REQUIRED, THRESHOLD BUILDING WORK ON 1ST FLOOR |
| | SLAB AFFECTING THE 1ST FLOOR TENANT ONLY |
| | 4) 3RD REQUEST. THE RESPONSE INDICATES THE BEER ALCOHOL |
| | CONTENT IS LESS THAN 16% IN THE MARGIN OF THE RESPONSE |
| | BUT NOT STATED ON THE LIFE SAFETY PLAN A1.0. |
| | THE PLANS INDICATE THIS IS A NEW BREWERY BUT THE PLANS |
| | ARE SILENT AS TO THE ALCOHOL CONTENT. PLEASE NOTE WHEN |
| | THE BEVERAGES HAVE AN ALCOHOL CONTENT OF OVER 16 PER |
| | CENT THEN THE BREWERY WOULD BE CLASSIFIED AS AN F1 |
| | OCCUPANCY AND OCCUPANCY SEPARATION MAY BE REQUIRED. SEE |
| | FBC-B TABLE 508.4. ONE HOUR REDUCTION FOR SPRINKLERED |
| | BUILDINGS. |
| | |
| | 5) 3RD REQUEST. IT WOULD APPEAR THAT IN THE MECHANICAL |
| | REVIEW COMMENT # 3 HAS NOT BEEN CLARIFIED WHAT IS THE |
| | WORKING PRESSURE. |
| | 2ND REVIEW COMMENT. QUESTION, DOESN?T ALL BREWERIES |
| | REQUIRE A BOILER AND 1 HOUR RATED ROOM. THE PLANS DO |
| | NOT SHOW THE BOILER NOR SIZE? PLEASE REVIEW THE 2014 |
| | FBC-B TABLE 509. ROOMS WITH BOILERS WHERE THE LARGEST |
| | PIECE OF EQUIPMENT IS OVER 15 PSI AND 10 HORSEPOWER |
| | WOULD REQUIRE 1 HOUR SEPARATION OR AUTOMATIC SPRINKLERS |
| | SYSTEM. |
| | |
| | 6-7)3RD. SEMI- COMPLIED / NEW COMMENT. EXTERIOR BAR |
| | REMOVED AND NEW EXIT DOOR ADDED ON THE EAST SIDE OF THE |
| | BUILDING. |
| | 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | 107.3.5.1.1. COMMERCIAL BUILDINGS: BUILDING. |
| | 8. STRUCTURAL REQUIREMENTS SHALL INCLUDE: |
| | BUILDING ENVELOPE |
| | WIND REQUIREMENTS |
| | |
| | 7) SEMI-COMPLIED. 2014 FBC-B 1603.1.4 WIND DESIGN DATA. |
| | THE SUBMITTED WIND DESIGN DOES NOT PROVIDE THE BUILDING |
| | MEAN ROOF HEIGHT, NEGATIVE PRESSURES ARE TAKEN FROM THE |
| | ROOF LEVEL. |
| | 8A) 3RD REQUEST. THIS CAN BE A PROVISO TO BE SUBMITTED |
| | AS A SUBMITTAL AFTER PERMIT ISSUANCE BUT ALL OF THE |
| | WIND DESIGN CRITERIA MUST BE KNOWN FOR THE CONTRACTOR |
| | TO BID THE WORK OUT. |
| | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS & MULLION |
| | (B) WINDOWS |
| | 7( C ) BUILDING PROVISO DEFERRED SUBMITTAL. SHEET S-2 |
| | WALL MOUNT MECHANICAL EQUIPMENT STAND TO BE SHOP |
| | DRAWINGS BY DELEGATE ENGINEER AND REVIEWED BY THE |
| | ENGINEER OF RECORD BEFORE BEING SUBMITTED TO THE |
| | BUILDING DEPARTMENT. |
| | |
| | 8B) NEW COMMENT DEALING WITH THE NEW EXIT DOOR ON THE |
| | EAST SIDE OF THE BUILDING. WITH AN OCCUPANT LOAD OF |
| | GREATER THAN 50 2 EXITS ARE REQUIRED, AND 2 ACCESSIBLE |
| | EXITS ARE REQUIRED. THERE IS A 2-3 INCH DIFFERENCE IN |
| | GRADE FROM THE INSIDE OF THE TENANT SPACE TO THE |
| | EXTERIOR SIDEWALK, HOW WILL THIS BE MADE TO COMPLY AS |
| | AN ACCESSIBLE EGRESS? |
| | |
| | 2014 FBC-ACCESSIBILITY CODE SECTION 207.1 MEANS OF |
| | EGRESS SHALL COMPLY WITH SECTION 1003.2.13 OF THE |
| | INTERNATIONAL BUILDING CODE (2000 EDITION AND 2001 |
| | SUPPLEMENT) OR SECTION 1007 OF THE INTERNATIONAL |
| | BUILDING CODE (2003 EDITION). |
| | |
| | 2003 IBC-B 1007.1 WHERE MORE THAN ONE MEANS OF EGRESS |
| | IS REQUIRED BY SECTIONS 1014.1 OR 1018.1 FROM ANY |
| | ACCESSIBLE SPACE, EACH ACCESSIBLE PORTION OF THE SPACE |
| | SHALL BE SERVED BY NOT LESS THAN TWO MEANS OF EGRESS. |
| | |
| | |
| | 9) PROVISO/ DEFERRED SUBMITTAL: W. P. B. 107.3.4.1 |
| | PRODUCT APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED |
| | BY THE DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | 10) COMPLIED. |
| | 11) SEMI-COMPLIED. SHEET A1.0 & A4.0 SHOWS WHAT APPEARS |
| | TO BEAN ACCESSIBLE BAR SECTION FOR THE INTERIOR BUT |
| | THERE IS NO INDICATION AS TO THE HEIGHT OF THE |
| | ACCESSIBLE PORTION OF THE BAR. 2014 FBC-ACCESSIBILITY |
| | CODE 902.3 HEIGHT. THE TOPS OF DINING SURFACES AND WORK |
| | SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES |
| | MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 12) SEMI-COMPLIED. 902.1 .DINING SURFACES AND WORK |
| | SURFACES SHALL COMPLY WITH 902.2 AND 902.3. ADVISORY |
| | 902.1 GENERAL. DINING SURFACES INCLUDE, BUT ARE NOT |
| | LIMITED TO, BARS, INCLUDING THE EXTERIOR BAR, TABLES, |
| | LUNCH COUNTERS, AND BOOTHS. |
| | |
| | 13)(A) 3RD REQUEST. SEMI-COMPLIED. 902.2 CLEAR FLOOR OR |
| | GROUND SPACE. A CLEAR FLOOR SPACE COMPLYING WITH 305 |
| | POSITIONED FOR A FORWARD APPROACH SHALL BE PROVIDED. |
| | KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE |
| | PROVIDED. |
| | |
| | 13)(B) 3RD REQUEST. 902.3 HEIGHT. THE TOPS OF DINING |
| | SURFACES AND WORK SURFACES SHALL BE 28 INCHES MINIMUM |
| | AND 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND. |
| | |
| | 14A-B) COMPLIED. |
| | |
| | 14C) 3RD REQUEST. RESPONSE INDICATES THE EXIT DOORS ARE |
| | NOTED ON SHEET A1.0 LIFE SAFETY EGRESS DRAWINGS INSTEAD |
| | OF A4.0, WHERE? |
| | SHEET A4.0 2014 FBC-B 1008.1.10 PANIC AND FIRE EXIT |
| | HARDWARE. DOORS SERVING ROOMS OR SPACES WITH AN |
| | OCCUPANT LOAD OF 50 OR MORE IN A GROUP A OCCUPANCY |
| | SHALL NOT BE PROVIDED WITH A LATCH OR LOCK UNLESS IT IS |
| | PANIC HARDWARE OR FIRE EXIT HARDWARE. |
| | |
| | 15) WHEN RESUBMITTING PLANS PLEASE INDICATE THE |
| | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES |
| | AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL |
| | REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE |
| | REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION |
| | PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO |
| | EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED |
| | COOPERATION. |
| | |
| | |