| Date |
Text |
| 2018-01-18 15:16:18 | NEW SINGLE FAMILY RESIDENCE (R3), PLUMBING REVIEW |
| | COMMENTS. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- REVISE PLUMBING RISER DIAGRAM ON SHEET P-1: |
| | A) NO MORE THAN ONE WET-VENTED FIXTURE DRAIN SHALL |
| | DISCHARGE UPSTREAM OF THE DRY-VENTED FIXTURE DRAIN |
| | CONNECTION. MASTER BATHROOM AND BATHROOM #1 SHOW TWO |
| | WET-VENTED FIXTURE DRAINS. (THE WATER CLOSET AND SHOWER |
| | OR TUB). REVISE AS REQUIRED BY SEC. P3108.2.1 |
| | FBC-RESIDENTIAL, 5TH EDITION (2014). |
| | |
| | B) PLUMBING RISER DIAGRAM IS MISSING THE DISHWASHER. |
| | REVISE AS REQUIRED. SEC. P2717 FBC-RESIDENTIAL. |
| | |
| | C) VENTING OF THE KITCHEN SINK IS NOT CLEAR. THERE IS |
| | NOT WALL BEHIND THE SINK. CLARIFY HOW THE VENTING IS |
| | PROVIDED. SEC. P3104.1 FBC-RESIDENTIAL. |
| | |
| | D) THERE ARE TWO SINKS IN THE MASTER BATHROOM. RISER |
| | ONLY SHOWS ONE. REVISE AS REQUIRED TO MATCH PLANS. SEC. |
| | 107.2.1 CITY AMENDMENTS. |
| | |
| | *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |
| | FOR REFERENCE AND HELP EXPEDITE THE REVIEW PROCESS. |
| | |
| | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |