| Date |
Text |
| 2017-12-29 09:00:01 | ****PLAN REVIEW COMMENTS**** |
| | |
| | ART LANGE BUILDING PLANS EXAMINER |
| | |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH, FL 33402 |
| | |
| | 561-805-6718 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | 1. THE NEW WALL CONTAINING THE BATHROOM DOOR BECOMES |
| | PART OF THE RATED CORRIDOR. |
| | PROVIDE CORRIDOR RATING. INCLUDE WALL RATING AND UL |
| | LISTING AS WELL AS THE DOOR RATING AND HARDWARE USED. |
| | |
| | FBC 716.5 TABLE OPENING FIRE PROTECTION ASSEMBLIES, |
| | RATINGS AND MARKINGS |
| | |
| | FBC 716.5.3 DOOR ASSEMBLIES IN CORRIDORS AND SMOKE |
| | BARRIERS. |
| | FIRE DOOR ASSEMBLIES REQUIRED TO HAVE A MINIMUM FIRE |
| | PROTECTION RATING OF 20 MINUTES WHERE LOCATED IN |
| | CORRIDOR WALLS OR SMOKE BARRIER WALLS HAVING A |
| | FIRE-RESISTANCE RATING IN ACCORDANCE WITH TABLE 716.5 |
| | SHALL BE TESTED IN ACCORDANCE WITH NFPA 252 OR UL 10C |
| | WITHOUT THE HOSE STREAM TEST. |
| | |
| | 2. DUCT PENETRATION THROUGH RATED WALL. SHOW HOW THIS |
| | WILL BE IN COMPLIANCE WITH FBC 717 DUCTS AND TRANSFER |
| | OPENINGS. |
| | |
| | |
| | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: |
| | |
| | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 |
| | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. |
| | |
| | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED |
| | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS |
| | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE |
| | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE |
| | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR |
| | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN |
| | THE PERMIT PACKAGE. |
| | |
| | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS |
| | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. |
| | |