| 2018-01-22 10:49:56 | 1. AN ENGINEERING DEVELOPMENT APPROVAL APPLICATION WILL |
| | BE REQUIRED FROM THE ENGINEERING SERVICES DEPARTMENT. |
| | THE ENGINEERING DEVELOPMENT APPROVAL APPLICATION FORMS |
| | CAN BE DOWNLOADED FROM THE FOLLOWING WEBSITE LINK: HTTP |
| | ://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FORMS,- |
| | PERMITS-APPLICATIONS |
| | |
| | 2. PLEASE SUBMIT THE LATEST VERSION OF THE 'AUTO-CALC |
| | CERTIFIED COST ESTIMATE FORM' FOR SUBMISSION TO CITY OF |
| | WEST PALM BEACH PUBLIC WORKS DEPARTMENT FOR ADDITIONAL |
| | WORK PROPOSED. THIS FORM CAN BE DOWNLOADED FROM THE |
| | FOLLOWING LINK: HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING- |
| | PUBLIC-WORKS/FORMS,-PERMITS-APPLICATIONS |
| | |
| | 3. MUST PROVIDE UTILITY CONFLICT TABLE (BOTTOM AND TOP |
| | OF CROSSING PIPES) AT THE CONFLICT POINTS OF ALL WATER, |
| | STORM AND SANITARY SEWER PIPES AS WELL AS OTHER |
| | FRANCHISE UTILITIES. EXISTING UTILITIES WITHIN THE |
| | PROPOSED SANITARY SEWER LATERAL ARE TO BE VERIFIED VIA |
| | SOFTDIGS, PROVIDE ALL UTILITY CROSSING INFORMATION; |
| | |
| | 4. FOR THE FINAL WATER AND SEWER PLANS, INCLUDE A NOTE |
| | THAT: AS OF DECEMBER 20, 2015 THE CITY OF WEST PALM |
| | BEACH CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, |
| | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD |
| | FREE." FOR MORE INFORMATION REFER TO THE LINK BELOW: HT |
| | TP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLICA |
| | TIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL |
| | |
| | 5. HOW WILL THE SITE/BUILDING BE SERVED FOR WATER, |
| | SEWER AND FIRE PROTECTION. SHOW ALL EXISTING UTILITIES |
| | WITHIN THE VICINITY OF THE PROPOSED SITE AS WELL AS |
| | PROPOSED UTILITIES TO SERVE THE DEVELOPMENT (LABEL SIZE |
| | AND MATERIAL OF ALL PIPES AND CONDUITS ETC.); |
| | |
| | 6. SUBMIT WITH THE ENGINEERING DEVELOPMENT APPROVAL |
| | APPLICATION SIGNED & SEALED ENGINEER/MEP WATER AND |
| | SANITARY SEWER CALCULATION (IN DETAIL I.E. AVERAGE AND |
| | PEAK WITH PEAKING FACTOR). SUBMIT CALCULATIONS TO |
| | VALIDATE METER SIZE SELECTION. SHOW THESE CALCULATIONS |
| | ON THE UTILITY PLAN SHEET AS WELL; |
| | |
| | 7. PROVIDE DRAINAGE CALCULATIONS; |
| | |
| | SOFIA QUINONES-BENEJAM, EI |