| 2018-04-24 09:33:37 | NEW SINGLE FAMILY RESIDENCE (R3), SECOND BUILDING |
| | REVIEW CHECKLIST. |
| | CODE: FBC 5TH EDITION (2014). |
| | |
| | 1- BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, |
| | ONE SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO |
| | PALM BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS |
| | WITH THE IMPACT FEE STAMP AND A COPY OF THE PAID |
| | RECEIPT MUST BE RETURNED TO THE CITY BUILDING |
| | DEPARTMENT BEFORE THE BUILDING PERMIT CAN BE ISSUED. |
| | FOR INFORMATION CALL PALM BEACH COUNTY IMPACT FEES AT |
| | (561) 233-5025. |
| | |
| | 2- COMPLIED. |
| | |
| | 3- SHEET A-1. REVISE THE EGRESS WINDOWS NOTE THAT IS |
| | LOCATED BELOW THE WINDOW SCHEDULE: |
| | A) COMPLIED. |
| | B) COMPLIED. |
| | C) COMPLIED. |
| | |
| | 4- COMPLIED. |
| | |
| | 5- RESPONSE: NOT ADDRESSED. NOTE: NEED DRAINAGE PLAN. |
| | SEE CITY AMENDMENTS SEC. 107.2.5 BELOW. |
| | |
| | ORIGINAL COMMENT: |
| | PROVIDE DRAINAGE PLAN SHOWING COMPLIANCE WITH SEC. |
| | R401.3 FBC-RESIDENTIAL. |
| | R401.3 DRAINAGE. |
| | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER |
| | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT |
| | DOES NOT CREATE A HAZARD. LOTS SHALL BE GRADED TO DRAIN |
| | SURFACE WATER AWAY FROM FOUNDATION WALLS. THE GRADE |
| | SHALL FALL A MINIMUM OF 6 INCHES (152 MM) WITHIN THE |
| | FIRST 10 FEET (3048 MM). |
| | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER |
| | PHYSICAL BARRIERS PROHIBIT 6 INCHES (152 MM) OF FALL |
| | WITHIN 10 FEET (3048 MM), DRAINS OR SWALES SHALL BE |
| | CONSTRUCTED TO ENSURE DRAINAGE AWAY FROM THE STRUCTURE. |
| | IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE |
| | BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 |
| | PERCENT AWAY FROM THE BUILDING. |
| | |
| | CITY AMENDMENTS SEC. 107.2.5 SITE PLAN. THE |
| | CONSTRUCTION DOCUMENTS SUBMITTED WITH THE APPLICATION |
| | FOR PERMIT SHALL BE ACCOMPANIED BY A SITE PLAN SHOWING |
| | TO SCALE THE SIZE AND LOCATION OF NEW CONSTRUCTION AND |
| | EXISTING STRUCTURES ON THE SITE, DISTANCES FROM LOT |
| | LINES, THE ESTABLISHED STREET GRADES AND THE PROPOSED |
| | FINISHED GRADES, DEPICTING THE PROPOSED LOT DRAINAGE |
| | AND, AS APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND |
| | DESIGN FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN |
| | ACCORDANCE WITH AN ACCURATE AND INCLUDED ON A BOUNDARY |
| | LINE SURVEY. IN THE CASE OF DEMOLITION, THE SITE PLAN |
| | SHALL SHOW CONSTRUCTION TO BE DEMOLISHED AND THE |
| | LOCATION AND SIZE OF EXISTING STRUCTURES AND |
| | CONSTRUCTION THAT ARE TO REMAIN ON THE SITE OR PLOT. |
| | THE BUILDING OFFICIAL IS AUTHORIZED TO WAIVE OR MODIFY |
| | THE REQUIREMENT FOR A SITE PLAN WHEN THE APPLICATION |
| | FOR PERMIT IS FOR ALTERATION OR REPAIR OR WHEN |
| | OTHERWISE WARRANTED. |
| | |
| | |
| | 6- ROOF PLAN ON SHEET S-1: |
| | A) RESPONSE: NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | SPECIFY THE CONNECTORS AT ALL ENDS OF ALL THE FRAMING |
| | MEMBERS SPECIFIED ON THE FRONT PORCH AREA. COORDINATE |
| | WITH DETAIL 1 ON SHEET A-3. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | B) RESPONSE: NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | FRAMING OF THE OUT-LOOKERS AT THE FRONT GABLE AREA. |
| | COORDINATE WITH DETAIL 1 ON SHEET A-3. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | C) RESPONSE: NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | PROVIDE COMPLETE DETAILS AND SPECIFICATIONS FOR THE |
| | BEAMS AT THE REAR PORCH. THERE IS NOT PRECAST LINTEL |
| | SCHEDULE. SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | 7- COMPLIED. |
| | |
| | 8- COMPLIED. |
| | |
| | 9- SHEET A-2: |
| | A) COMPLIED?. |
| | |
| | B) COMPLIED. |
| | |
| | C) SEMI-COMPLIED. NOTE: IF THERE IS ANY DISCREPANCY |
| | BETWEEN THE REFERENCED MANUAL AND FBC AND PRODUCT |
| | APPROVAL SUBMITTED, THEN FBC AND PRODUCT APPROVAL |
| | PREVAILS. |
| | |
| | ORIGINAL COMMENT: |
| | CLARIFY WHY REFERENCING "THE ARMA RESIDENTIAL ROOFING |
| | MANUAL 2006". THIS STANDARD IS NOT REFERENCED IN THE |
| | FLORIDA BUILDING CODE. SEE SEC. R905.2 FBC-RESIDENTIAL |
| | AND REVISE AS REQUIRED. REVISE AS REQUIRED ON WALL |
| | SECTIONS #5 AND #6. NOTE: REVISE DETAIL #2 ON SHEET A-3 |
| | AND DETAIL #1 ON SHEET A-4 AS WELL. |
| | |
| | D) COMPLIED. |
| | |
| | 10- SECTION 5 ON SHEET S-3: |
| | A) RESPONSE: NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | PROVIDE COMPLETE SPECIFICATIONS FOR THE BASE PLATE |
| | FASTENERS. SPECIFY HOW MUCH EMBEDMENT IS REQUIRED. WHAT |
| | DOES H.S STANDS FOR?. THERE IS NOT ABBREVIATION LEGEND. |
| | NOTE: COORDINATE INFORMATION WITH STEEL COLUMN SCHEDULE |
| | ON SHEET S-1, INCLUDING SIZE OF PLATE. REVISE AS |
| | REQUIRED TO MATCH. SEC. R301.1 FBC-RESIDENTIAL. |
| | |
| | |
| | B) RESPONSE: NOT ADDRESSED. |
| | |
| | ORIGINAL COMMENT: |
| | WELDING INFORMATION FOR THE STEEL COLUMN AT TOP AND |
| | BOTTOM PLATES IS INCOMPLETE. ONLY THE WELDING SYMBOL IS |
| | PROVIDED. PROVIDE COMPLETE SPECIFICATIONS. SEC. R301.1 |
| | FBC-RESIDENTIAL. |
| | |
| | 11- REVISE ENERGY CALCULATIONS SUBMITTED: |
| | A) COMPLIED. |
| | |
| | B) COMPLIED. |
| | |
| | C) COMPLIED. |
| | |
| | D) COMPLIED. |
| | |
| | E) COMPLIED. |
| | |
| | 12- PROVIDE PRODUCT APPROVAL (2 COPIES) FOR: (NOTE: ALL |
| | PRODUCT APPROVALS WILL BE SUBMITTED LATER AS DEFERRED |
| | SUBMITTAL) |
| | A) ENTRY DOOR WITH SIDELITES AND TRANSOM AS SHOWN ON |
| | PLANS. |
| | B) SINGLE HUNG WINDOWS AS SPECIFIED ON PLANS. |
| | C) HORIZONTAL ROLLER WINDOWS AS SPECIFIED ON PLANS. |
| | D) SLIDING GLASS DOORS AS SHOWN ON PLANS. |
| | E) HURRICANE SHUTTERS IF DOORS AND WINDOWS DON'T HAVE |
| | HURRICANE IMPACT GLAZING. AND, PROVIDE COMPLETE |
| | INSTALLATION SCHEDULE. SEE CITY SAMPLE. |
| | F) ROOF SHINGLES. |
| | G) ROOF SHINGLES UNDERLAYMENT AS SPECIFIED ON PLANS. |
| | H) RIDGE VENTS AS SPECIFIED ON PLANS. SEE SHEET A-1. |
| | I) PRECAST LINTELS AS SPECIFIED ON PLANS. |
| | |
| | 13- DESIGNER OF RECORD TO REVIEW AND APPROVE ALL |
| | PRODUCT APPROVALS (NOT SIGNING AND SEALING). |
| | |
| | 14- VALUE DECLARED IN THE PERMIT APPLICATION IS TOO |
| | LOW. VALUE TO INCLUDE ALL LABOR, MATERIALS, |
| | CONTRACTOR'S OVERHEAD AND PROFIT AND ALL DESIGN |
| | PROFESSIONAL FEES AS REQUIRED BY SEC. 109.3 CITY |
| | AMENDMENTS. VALUATION WAS UPDATED TO $192,608. THE |
| | PERMIT FEE BALANCE IS $3,674.29. |
| | NOTE: PROVIDE COPY OF THE CONSTRUCTION CONTRACT/COST |
| | BREAKDOWN AS REQUESTED BY ROBERT BROWN (BUILDING |
| | OFFICIAL). COORDINATE WITH ARMANDO FANA. DIRECTOR, |
| | HOUSING AND COMMUNITY DEVELOPMENT. |
| | |
| | |
| | *****PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH |
| | COMMENT TO HELP EXPEDITE THE REVIEW PROCESS. |
| | ****PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD |
| | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS |