| 2018-01-04 14:33:30 | PLAN |
| | REVIEW COMMENTS |
| | |
| | 1ST REVIEW: FBC FIFTH EDITION (2014) |
| | ROBERT MCDOUGAL, CBO |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | (561) 805-6714 |
| | [email protected] |
| | |
| | DENIED BY BUILDING |
| | PLEASE ADDRESS THE ITEMS NOTED BELOW: |
| | |
| | 1) THE VALUE OF $9,200.00 STATED ON THE REVISION |
| | APPLICATION IS NOT ADEQUATE FOR THE ADDITIONAL SCOPE |
| | SPECIFIED ON THE DRAWING THAT WAS SUBMITTED. PROVIDE AN |
| | ITEMIZED COST BREAK DOWN FOR THE PROPOSED REVISED SCOPE |
| | OF WORK WITH AN ACCURATE TOTAL VALUE. FBC 109.3 |
| | BUILDING PERMIT VALUATION. FOR PERMITTING PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE TOTAL |
| | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRIC, |
| | PLUMBING, MECHANICAL, INTERIOR FINISH, RELATIVE SITE |
| | WORK, ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, |
| | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. |
| | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED |
| | DATA OF NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY |
| | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT |
| | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. |
| | |
| | 2) SUBMIT TWO SETS OF A FLOOR PLAN THAT ACCURATELY |
| | SHOWS AND DESCRIBES THE EXISTING CONDITIONS. FBC |
| | 107.2.1 |
| | |
| | 3) THE PLANS THAT WERE SUBMITTED DO NOT MATCH THE PALM |
| | BEACH COUNTY PROPERTY APPRAISER'S RECORDS. SHOW THE |
| | ENTIRE STRUCTURE THAT IS UNDER ROOF ON THE PLANS |
| | INCLUDING CARPORTS, PORCHES, ETC. IF THE EXISTING |
| | STRUCTURE DOES NOT MATCH THE PROPERTY APPRAISER'S |
| | DIAGRAM, EXPLAIN THE DIFFERENCES. FBC 107.2.1 |
| | |
| | 4) PROVIDE EXISTING AND PROPOSED AREA TABULATIONS ON |
| | THE PLANS. FBC 107.2.1 |
| | |
| | 5) FBC 107.3.4 - PROVIDE TWO SETS OF PRODUCT APPROVALS |
| | FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC |
| | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE |
| | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER |
| | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH |
| | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS |
| | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE |
| | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR |
| | DOOR TYPES. IF THE WINDOWS ARE NOT LARGE MISSILE IMPACT |
| | RATED, THEN SUBMIT PRODUCT APPROVALS FOR THE STORM |
| | PANELS ALONG WITH A KEY PLAN AND INSTALLATION SCHEDULE. |
| | |
| | 6) SHOW HOW THE BEDROOM WINDOWS WILL COMPLY WITH |
| | FBC-R310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. |
| | BASEMENTS, HABITABLE ATTICS AND EVERY SLEEPING ROOM |
| | SHALL HAVE AT LEAST ONE OPERABLE EMERGENCY ESCAPE AND |
| | RESCUE OPENING. |
| | |
| | FBC-R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE |
| | AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR |
| | OPENING OF 5.7 SQUARE FEET. EXCEPTION: GRADE FLOOR |
| | OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 |
| | SQUARE FEET. |
| | |
| | FBC-R310.1.2 MINIMUM OPENING HEIGHT. |
| | THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 |
| | INCHES. |
| | |
| | FBC-R310.1.3 MINIMUM OPENING WIDTH. |
| | THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES. |
| | |
| | 7) SPECIFY THE OCCUPANCY TYPE ON THE PLANS. FBC 107.2.1 |
| | |
| | 8) SPECIFY THE EXPOSURE CATEGORY OF THE PROJECT ON THE |
| | PLANS. FBC-R301.2.1.4 |
| | |
| | 9) THE APPROVED PLANS WILL NEED TO BE REVIEWED BY PALM |
| | BEACH COUNTY TO DETERMINE IF ANY IMPACT FEES ARE DUE. |
| | SEE THE IMPACT FEE REVIEW FOR DETAILS. |
| | |
| | 10) IN ORDER TO REDUCE PLAN REVIEW TIME, PLEASE SUBMIT |
| | A RESPONSE LETTER INDICATING HOW EACH OF THE REVIEW |
| | COMMENTS HAS BEEN ADDRESSED. |
| | |
| | |
| | |
| | |