2017-12-27 12:26:58BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 CHOOSE ONE OF THE FOLLOWING AND SUBMIT APPROPRIATE
 DOCUMENTS:
  
 1. PRE-ENGINEERED SHED
 A. PROVIDE FOUNDATION PLAN.
 B. PROVIDE PRE-ENGINEERED DESIGN.
 C. IDENTIFY TYPE OF TIE-DOWN TO FOUNDATION.
 D. PROVIDE SITE PLAN WITH LOCATION OF PROPOSED SHED.
  
 2. SITE BUILT SHED
 A. PROVIDE FOUNDATION PLAN ? FOOTINGS/SLAB ON
 GRADE/RE-INFORCING
 B. PROVIDE BUILDING PLANS ?
 1. FLOOR
 2. WALLS
 3. ROOF FRAMING
 C. WINDOW AND/OR DOOR SCHEDULE WITH ROUGH OPENINGS AND
 DESIGN WIND LOADS PER CHPT. 3 FBC RESIDENTIAL.
 D. PRODUCT APPROVALS FOR ALL ROOFING, WINDOWS AND/OR
 DOORS, REVIEWED AND APPROVED BY DESIGNER.
 E. PROVIDE SITE PLAN WITH SETBACKS TO PROPERTY LINES
 AND ANY EXISTING STRUCTURES.
  
  