| Date |
Text |
| 2018-01-29 13:51:21 | 1ST REVIEW: FBC 2014 5TH EDITION |
| | |
| | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED WITH. |
| | |
| | 4.HOW WILL THIS BE COMPLIED WITH 110DEG SHOWN ON THE |
| | ISOMETRIC DRAWING IS NOT SUFFICIENT PROVIDE MANUFACTURE |
| | AND MODEL NUMBER INDICATE WITH NOTE ON PLAN. TEMPERED |
| | WATER SHALL BE DELIVERED FROM LAVATORIES AND GROUP WASH |
| | FIXTURES LOCATED IN PUBLIC TOILET FACILITIES PROVIDED |
| | FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED WATER |
| | SHALL BE DELIVERED THEOUGH AN APPROVED |
| | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE |
| | 1070 OR CSA B125.3. PER FBC PL 416.5 |
| | |
| | 5. PLEASE PROVIDE MANUFACTURE SPECS AND INSTALLATION |
| | GUIDE FOR GREASE TRAP MANUFACTURE SPECIFICATIONS THAT |
| | WAS PROVIDED DID NOT SHOW THE PDI CERTIFICATION OR ANY |
| | OTHER STANDARD NUMBER THAT IT COMPLIES WITH. IT WAS NOT |
| | A INSTALLATION GUIDE . PER WPB AMEND TO FBC 107.2.1 |
| | |
| | NEW COMMENTS: |
| | |
| | 1. THE LOCATION OF THE GREASE INTERCEPTOR UNDER THR |
| | THREE COMPARTMENT SINK WILL NOT ALLOW IT TO BE SERVICED |
| | IT SHOULD BE IN AN OPEN FLOOR AREA WERE THE LID CAN BE |
| | REMOVED AND INTERCEPTOR BE CLEANED OUT FROM ABOVE. PER |
| | FBC PL 1003.2 |
| | |
| | 2. PLEASE SHOE CLEAR FLOOR SPACE FOR TOILET AND |
| | LAVATORY. PER FBC ACC |
| | 604.3.1 SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE |
| | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE |
| | WALL AND 56 INCHES MINIMUM MEASURED PERPENDICULAR FROM |
| | THE REAR WALL. |
| | 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING |
| | WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE |
| | AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 3. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND |
| | SHALL BE 7 INCHES MINIMUM AND 9 INCHES MAXIMUM IN FRONT |
| | OF THE WATER CLOSET MEASURED TO THE CENTERLINE OF THE |
| | DISPENSER. PER FBC ACC 604.7 |
| | |
| | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID |
| | THE PREVIOUSLY REVIEWED SHEETS. |
| | |
| | GEORGE JOHNSON |
| | PLUMBING PLANS EXAMINER |
| | CITY OF WEST PALM BEACH |
| | 561-805-6711 |
| | [email protected] |
| | |