| Date |
Text |
| 2020-10-30 17:22:37 | NEW SINGLE FAMILY RESIDENCE R3) BUILDING REVIEW |
| | COMMENTS |
| | CODE: FBC 6TH EDITION (2017) AND CITY AMENDMENTS. |
| | |
| | 1- ENERGY CALCULATIONS: |
| | THE ENERGY FORM R405-2017 IS REQUIRED TO BE SIGNED AND |
| | DATED BY THE OWNER, ARCHITECT OR OWNER'S LEGALLY |
| | DESIGNATED AGENT AT THE BOTTOM OF FORM SUBMITTED AS |
| | REQUIRED BY SEC. R103.1.1.2 FBC-ENERGY CONSERVATION, |
| | 6TH EDITION (2017) PRIOR TO RECEIVING THE PERMIT TO |
| | BEGIN CONSTRUCTION. |
| | |
| | 2- STRUCTURAL DRAWINGS S1, S2, S3 AND S4 WERE NOT |
| | UPLOADED FOR REVIEW. NEED TO UPLOAD THESE DRAWINGS. |
| | SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 3- IT LOOKS LIKE SECOND FLOOR SINGLE HUNG EGRESS |
| | WINDOWS #2 HAVE THE WINDOW SILL LOCATED LESS THAN 24 |
| | INCHES ABOVE THE FINISH FLOOR. NEED TO COMPLY WITH THE |
| | WINDOW FALL PROTECTION SEC. R312.2 FBC-RESIDENTIAL. |
| | PROVIDE COMPLETE DETAILS AND SPECIFICATIONS SHOWING |
| | COMPLIANCE. |
| | |
| | 4- PROVIDE BOUNDARY LINE SURVEY AS REQUIRED BY SEC. |
| | 107.2.5 CITY AMENDMENTS. |
| | PROVIDE SURVEY WITH ORIGINAL SEAL/SIGNATURE (DIGITAL |
| | SIGNATURE OR HARDCOPY ORIGINAL) AS REQUIRED BY CHAPTER |
| | 472 FLORIDA STATUTES WHEN SUBMITTING DOCUMENTS FOR |
| | PUBLIC RECORDS. |
| | |
| | 5- MERRY PLACE LOT GRADING SHEET C1: |
| | A) DRAWING C1 WAS UPLOADED IN THE "SUPPORTING |
| | DOCUMENTS" FOLDER INSTEAD OF THE "DRAWINGS" FOLDER. ALL |
| | DRAWINGS NEED TO BE UPLOADED IN THE "DRAWINGS" FOLDER |
| | (WITH PROPER DIGITAL SIGNATURE) AS REQUIRED BY THE CITY |
| | DIGITAL PLAN REVIEW INSTRUCTIONS AND SEC. 107.2.1.3 |
| | CITY AMENDMENTS FOR PROPER RECORDS RETENTION. |
| | |
| | B) DRAWING C1 SHOWS DETAIL SECTIONS A/C2 AND B/C2. |
| | WHERE ARE THESE DETAILS?. SHEET C2 WAS NOT UPLOADED. |
| | PROVIDE THESE DETAILS AND REVISE DETAIL REFERENCE |
| | ACCORDINGLY. SEC. 107.2.1 CITY AMENDMENTS. |
| | |
| | 6-DEFERRED SUBMITTALS: |
| | WINDOWS, DOORS, ROOFING AND ROOF VENTS, ALUMINUM |
| | SOFFITS, RAILINGS AND GUARDRAILS. |
| | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE |
| | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN |
| | RESPONSIBLE CHARGE FOR REVIEW PRIOR TO SUBMITTAL TO |
| | THIS OFFICE. SEC. 107.3.4.1 CITY AMENDMENTS. |
| | |
| | 7- VALUATION DECLARED IN THE PERMIT APPLICATION IS LOW. |
| | VALUATION TO INCLUDE ALL LABOR, MATERIALS, CONTRACTOR'S |
| | OVERHEAD AND PROFIT AND DESIGN PROFESSIONAL FEES AS |
| | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS |
| | UPDATED TO $229,850. THE PERMIT FEE BALANCE IS |
| | $4399.29. |
| | |
| | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY |
| | QUESTIONS REGARDING THESE COMMENTS, |
| | JULIO GOMEZ |
| | COMMERCIAL COMBINATION PLANS EXAMINER |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | BUILDING DIVISION |
| | (561)805-6712 |
| | [email protected] |