Plan Review Notes
Plan Review Notes For Permit 17120220
Permit Number 17120220
Review Stop Z
Sequence Number 1
Notes
Date Text
2017-12-19 11:32:40** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) PROVIDE A SIGNED AND SEALED ABSTRACTED SURVEY OF
 THE PROPERTY. THERE SEEMS TO BE AN EASEMENT RUNNING
 ALONG THE REAR OF THE PROPERTY; HOWEVER, THIS IS NOT
 SHOWN IN THE SURVEY BECAUSE IT IS NOT ABSTRACTED. AN
 ABSTRACTED SURVEY IS NECESSARY TO DETERMINE THE
 PLACEMENT OF STRUCTURES ON THE PROPERTY. PLEASE NOTE
 THAT NO STRUCTURES CAN BE BUILT WITHIN AN EASEMENT,
 UNLESS EASEMENT CONSENT HAS BEEN PROVIDED.
  
 2.) HOW HIGH IS THE PROPOSED WALL ALONG THE SIDE AND
 REAR OF THE PROPERTY? PLEASE NOTE THAT THE WALL CANNOT
 EXCEED 6 FT. IN HEIGHT (HEIGHT WILL BE MEASURED FROM
 THE OUTSIDE OF THE WALL). [ZLDR S.94-302]
  
 3.) SWIMMING POOL MUST BE SETBACK AT LEAST 5 FT. FROM
 THE WATER'S EDGE TO THE PROPERTY LINES AT THE SIDE AND
 REAR. PLEASE NOTATE TO DEMONSTRATE COMPLIANCE WITH
 ZONING AND LAND DEVELOPMENT REGULATIONS (ZLDRS). [ZLDR
 S.94-304]
  
 4.) THE PATIO SURROUNDING THE POOL SHALL BE DESIGNED TO
 DRAIN AWAY FROM THE POOL, BUT NOT ONTO ADJACENT
 PROPERTIES. [ZLDR S.94-304]
  
 5.) MECHANICAL EQUIPMENT MAY NOT PROJECT MORE THAN 4
 FT. INTO A REQUIRED SETBACK. PLEASE SHOW SETBACK
 DISTANCE OF THE A/C UNITS, POOL EQUIPMENT, ETC. FROM
 THE PROPERTY LINES. [ZLDR S.94-305]
  
 6.) STEPS AND PORCHES THAT ARE 3 FT. OR LESS ABOVE
 GRADE SHALL BE SETBACK AT LEAST 2 FT. FROM THE PROPERTY
 LINE. [ZLDR S.94-304]
  
 7.) STRUCTURAL OVERHANGS, INCLUDING BALCONIES,
 CORNICES, GUTTERS, EAVES, AND ROOF OVERHANG PROJECTIONS
 SHALL NOT EXTEND FATHER THAN 3 FT. INTO ANY SETBACK.
 SHOW DIMENSIONS TO DEMONSTRATE COMPLIANCE. [ZLDR
 S.94-305]
  
 8.) A MINIMUM OF 1,000 SQ. FT. OR 75 PERCENT OF THE
 REQUIRED FRONT YARD (THE AREA WITHIN THE FIRST 25 FT.
 OF THE FRONT PROPERTY LINE ON WINDSOR AVE.) SHALL BE
 LANDSCAPED WITH LIVING PLANT MATERIAL (I.E. GRASS,
 GROUND COVER, SHRUBS, HEDGES, VINES OR TREES). PLEASE
 SHOW CALCULATIONS IN THE REQUESTED SITE PLAN TO
 DEMONSTRATE COMPLIANCE. [ZLDR S.94-482(A)]
  
 9.) THE PROPOSED CIRCULAR DRIVE SHALL NOT EXCEED 10 FT.
 IN WIDTH AT THE PROPERTY LINE OR WHERE THE DRIVEWAY
 OPENING ADJOINS THE APRON IF THE APRON IS NOT LOCATED
 WHOLLY WITHIN THE RIGHT-OF-WAY. ADDITIONALLY, A MINIMUM
 5 FT. RADIUS SHALL BE PROVIDED FOR THE CIRCULAR DRIVE.
 PLEASE SHOW DIMENSIONS. [ZLDR S.394-312]
  
 10.) SHOW SETBACK DISTANCE FROM THE PROPOSED DRIVEWAY
 TO THE SIDE CORNER PROPERTY LINE.
  
 11.) THE WOOD TRELLIS SHALL BE SETBACK AT LEAST 5 FT.
 FROM THE SIDE AND REAR PROPERTY LINES. SHOW DIMENSIONS
 TO DEMONSTRATE COMPLIANCE. [ZLDR S.94-305]
  
  
 NOTES:
  
 * SEPARATE PERMITS REQUIRED PRIOR TO THE ISSUANCE OF A
 CERTIFICATE OF OCCUPANCY (C.O.): LANDSCAPING, SWIMMING
 POOL, WALL AND DRIVEWAY.
  
 * CONSULT WITH THE BUILDING DEPARTMENT ON THE DISTANCE
 OF THE POOL FROM THE OVERHEAD LINES ALONG THE REAR
 PROPERTY LINE.
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  
 * POOL WALL/FOUNTAIN ALONG REAR AND SIDES SEEMS TO
 ENCROACH INTO AN EASEMENT.
  
 * ZONE: SF7
  