| Date |
Text |
| 2018-01-12 17:29:05 | BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 16050779 |
| | ADD: 2161PALM BEACH LAKES BLVD 1ST FLOOR |
| | CONT: ALL PHASE CONSTRUCTION |
| | TEL: 561-723-8246 |
| | E-MAIL:[email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: FRI. JAN 11/2018 |
| | ACTION: DENIED |
| | |
| | 1) SEMI-COMPLIED. SHEET C-1 THE COVERSHEET HAS A INDEX, |
| | MISSING SHEETS: |
| | SHEET 1.5A SECTIONS & DETAILS |
| | |
| | 2-4D) COMPLIED |
| | |
| | 4D)SEMI- COMPLIED. SEE 4E. NEITHER SHEET 1.2A NOR 1.4A |
| | SHOW COMPLIANCE WITH COMPLIANCE WITH 2014 FBC-ACCESS. |
| | CODE 226.1. WHERE DINING SURFACES ARE PROVIDED FOR THE |
| | CONSUMPTION OF FOOD OR DRINK, AT LEAST 5 PERCENT OF THE |
| | SEATING SPACES AND STANDING SPACES AT THE DINING |
| | SURFACES SHALL COMPLY WITH 902. THE COVERSHEET LIST 292 |
| | SEATS X 0.05 = 15 ACCESSIBLE SEATS. |
| | ACTUAL SEATING COUNT OF 343 X 0.05 = 18 ACCESSIBLE |
| | SEATS. |
| | |
| | 4E) 2ND REQUEST. PLEASE PROVIDE A CUT SECTION THROUGH |
| | THE ACCESSIBLE BAR TOPS SHOWING THE ELEVATION. CAN NOT |
| | BE A DROPPED LEAF DESIGN. |
| | 1ST ROUND COMMENTS. PLEASE NOTE COMPLIANCE WITH ACCESS. |
| | CODE 226.2 DISPERSION. DINING SURFACES AND WORK |
| | SURFACES REQUIRED TO COMPLY WITH 902 SHALL BE DISPERSED |
| | THROUGHOUT THE SPACE OR FACILITY CONTAINING DINING |
| | SURFACES AND WORK SURFACES. |
| | |
| | 4F)SHOW COMPLIANCE WITH FBC-ACCESS. CODE 902.1DINING |
| | SURFACES AND WORK SURFACES SHALL COMPLY WITH 902.2 AND |
| | 902.3. |
| | |
| | 4F)(1) FBC-ACCESS. 902.2 CLEAR FLOOR OR GROUND SPACE. A |
| | CLEAR FLOOR SPACE COMPLYING WITH 305 POSITIONED FOR A |
| | FORWARD APPROACH SHALL BE PROVIDED. KNEE AND TOE |
| | CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED. |
| | |
| | 4F)(2) FBC-ACCESS. 902.3 HEIGHT. THE TOPS OF DINING |
| | SURFACES SHALL BE 28 INCHES AND 34 INCHES MAXIMUM ABOVE |
| | THE FINISH FLOOR OR GROUND. |
| | |
| | 5) DELETED FROM PROJECT. SHEET 1.2A NOTE 10 INDICATES |
| | THE REMOVAL AND REPLACEMENT OF EXTERIOR SLIDING GLASS |
| | DOORS. PLEASE PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| | BUILDING. PLEASE ALSO PROVIDE THE PRESSURES IN VASD. |
| | PLEASE SHOW COMPLIANCE WITH: |
| | |
| | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS |
| | (B) WINDOWS |
| | |
| | 5B) DELETED FROM PROJECT. W. P. B. 107.3.4.1 PRODUCT |
| | APPROVALS. THOSE PRODUCTS WHICH ARE REGULATED BY THE |
| | DCA RULE 9N-03 SHALL BE REVIEWED AND APPROVED IN |
| | WRITING BY THE DESIGNER OF RECORD PRIOR TO SUBMITTAL |
| | FOR JURISDICTIONAL APPROVAL. FL 61G1-23.015 (2) THE |
| | ARCHITECT IS RESPONSIBLE FOR SUPERVISING AND REVIEWING |
| | ALL PROJECT DATA, REPORTS, SHOP DRAWINGS ETC.. |
| | |
| | 6) PLEASE PROVIDE A LIST HOW UP TO AN ADDITIONAL |
| | $24,000.00 DOLLARS WILL BE SPENT IN ACCESSIBLE |
| | UPGRADES. 2014 FBC-ACCESS. CODE 202.4.1 |
| | DISPROPORTIONATE COST. |
| | ALTERATIONS MADE TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL TO THE ALTERED AREA WILL BE DEEMED |
| | DISPROPORTIONATE TO THE OVERALL ALTERATION WHEN THE |
| | COST EXCEEDS 20% OF THE COST OF THE ALTERATION TO THE |
| | PRIMARY FUNCTION AREA. COSTS THAT MAY BE COUNTED AS |
| | EXPENDITURES REQUIRED TO PROVIDE AN ACCESSIBLE PATH OF |
| | TRAVEL MAY INCLUDE: (I) COSTS ASSOCIATED WITH PROVIDING |
| | AN ACCESSIBLE ENTRANCE AND AN ACCESSIBLE ROUTE TO THE |
| | ALTERED AREA; (II) COSTS ASSOCIATED WITH MAKING |
| | RESTROOMS ACCESSIBLE, SUCH AS INSTALLING GRAB BARS, |
| | ENLARGING TOILET STALLS, INSULATING PIPES, OR |
| | INSTALLING ACCESSIBLE FAUCET CONTROLS; (III) COSTS |
| | ASSOCIATED WITH PROVIDING ACCESSIBLE TELEPHONES, SUCH |
| | AS RELOCATING THE TELEPHONE TO AN ACCESSIBLE HEIGHT, |
| | INSTALLING AMPLIFICATION DEVICES, OR INSTALLING A TEXT |
| | TELEPHONE (TTY); (IV) COSTS ASSOCIATED WITH RELOCATING |
| | AN INACCESSIBLE DRINKING FOUNTAIN. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |