| 2017-12-05 15:56:57 | APPROVED WITH EXCEPTION | | | THIS PLAN HAS BEEN APPROVED PROVISIONALLY. FAILURE TO | | | CORRECT THE LISTED DEFICIENCIES IN THIS PLAN PRIOR TO | | | INSPECTION WILL RESULT IN FAILED INSPECTION(S) AND THE | | | ASSESSMENT OF RE-INSPECTION FEE(S). | | | 1) SUBMIT TWO COPIES OF THE TEST REPORTS FOR THE SOUND | | | INSULATION INCLUDING FLAME SPREAD AND SMOKE DEVELOPED | | | FOR THE APPLICABLE CONSTRUCTION CONDITIONS THAT IS | | | REQUIRED FOR THE NEW TILE FLOORING. TEST REPORTS MAY BE | | | BASED ON THE FOLLOWING ASTM'S: E-84, E-90 & E-492. FBC | | | 603.1 FLAME SPREAD - ASTM E 84-09, FBC 1207.2 AIR-BORNE | | | SOUND - ASTM E 90-04 AND FBC 1207.3 STRUCTURE-BORNE | | | SOUND - ASTM E 492-09. |
|