| 2017-12-27 13:37:00 | ****PLAN REVIEW COMMENTS**** |
| | |
| | ART LANGE BUILDING PLANS EXAMINER |
| | |
| | DEVELOPMENT SERVICES DEPARTMENT |
| | 401 CLEMATIS STREET |
| | WEST PALM BEACH, FL 33402 |
| | |
| | 561-805-6718 [email protected] |
| | |
| | FBC FLORIDA BUILDING CODE 2014 5TH EDITION W/2010 WEST |
| | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, |
| | CHAPTER 1 ADMINISTRATION |
| | |
| | 1) PLEASE UPDATE DEMO KEY NOTES TO INCLUDE #12 AND #13 |
| | THAT ARE NOT SHOWN ON PAGE AD1.1. ON PAGE A-2.01 |
| | ELEVATION #6 NOTE SHOWN AS NEEDED. |
| | |
| | 2) PROVIDE STRUCTURAL SHOP DRAWINGS FOR AWNING SHOWN AS |
| | KEY NOTE #7 ON A-2.0.1. |
| | |
| | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING |
| | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA |
| | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION |
| | PLAN; FLOOR/ROOF FRAMING PLAN OR TRUSS LAYOUT; ALL |
| | FENESTRATION PENETRATIONS; FLASHING; AND ROUGH OPENING |
| | DIMENSIONS; AND ALL EXTERIOR ELEVATIONS. |
| | |
| | 3) PROVIDE PRODUCT APPROVAL FOR TRULITE DOOR USED WITH |
| | THE TRULITE STOREFRONT WALL SYSTEM. IT HAS ITS OWN |
| | PRODUCT APPROVAL. |
| | |
| | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE |
| | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED |
| | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. |
| | |
| | 4) ON LIFE SAFETY ALS.1.1 THE SECOND EXIT SHOWN IS |
| | THROUGH A STORAGE ROOM. |
| | |
| | FBC 1014.2 EGRESS THROUGH INTERVENING SPACES. |
| | |
| | EGRESS THROUGH INTERVENING SPACES SHALL COMPLY WITH |
| | THIS SECTION. |
| | |
| | 1. EGRESS FROM A ROOM OR SPACE SHALL NOT PASS THROUGH |
| | ADJOINING OR INTERVENING ROOMS OR AREAS, EXCEPT WHERE |
| | SUCH ADJOINING ROOMS OR AREAS AND THE AREA SERVED ARE |
| | ACCESSORY TO ONE OR THE OTHER, ARE NOT A GROUP H |
| | OCCUPANCY AND PROVIDE A DISCERNIBLE PATH OF EGRESS |
| | TRAVEL TO AN EXIT. |
| | |
| | 4. EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE |
| | ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. |
| | EXCEPTIONS: 2.2. NOT MORE THAN 50 PERCENT OF THE EXIT |
| | ACCESS IS THROUGH THE STOCKROOM. |
| | NOTE: THIS EGRESS DOES NOT EXCEED THE 50 PERCENT |
| | ALLOWED BY EXCEPTION 2.2. BUT SHALL COMPLY WITH FBC |
| | 1014.2 EXCEPTION 2. AN EXIT ACCESS SHALL NOT PASS |
| | THROUGH A ROOM THAT CAN BE LOCKED TO PREVENT EGRESS. |
| | |
| | 5) PROVIDE THE STORAGE CLASSIFICATION FOR THE EXISTING |
| | STORAGE AREA AND ITS COMPLIANCE WITH FBC 311 STORAGE |
| | GROUP S. BASED ON THIS DETERMINATION. INCLUDE |
| | INFORMATION ON THE DOOR, RATING AND IF A CLOSURE WILL |
| | BE PROVIDED AND IF THE WINDOW WILL BE PROVIDED WITH A |
| | RATING. |
| | |
| | WHEN RESUBMITTING, PLEASE COMPLETE A RESUBMITTAL FORM: |
| | |
| | HTTP://WPB.ORG/DEVELOPMENT/WPCONTENT/UPLOADS/SITES/33/2 |
| | 013/09/APPLICATION_RESUBMITTAL_FORM_04132010.PDF |
| | |
| | THIS FORM IS ALSO AVAILABLE AT THE BUILDING DIVISION. |
| | |
| | WHEN RESUBMITTING, SWAP OUT SHEETS WHICH HAVE CHANGED |
| | SO THAT THERE ARE TWO COMPLETE, COLLATED SETS OF PLANS |
| | READY FOR PERMIT ISSUANCE. OLD SHEETS ARE TO BE |
| | RETAINED IN THE PERMIT APPLICATION PACKAGE (SEPARATE |
| | FROM THE PERMIT SETS) AND MARKED *OLD SHEETS* OR |
| | *VOID*. PLEASE KEEP BOTH SETS OF OLD VOIDED SHEETS IN |
| | THE PERMIT PACKAGE. |
| | |
| | A RESPONSE LETTER INDICATING HOW EACH ITEM WAS |
| | ADDRESSED WILL HELP TO EXPEDITE PLAN REVIEW. |
| | |