| 2017-12-11 13:28:26 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17120018 / PARTIAL CHANGE IN |
| | OCCUPANCY. |
| | ADD: 854 CONNISTON RD. |
| | CONT: TBD/ TO BE DETERMINED |
| | TEL: 561-400-1804 / CAMILA SA |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW |
| | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES |
| | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA |
| | BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: MON. DEC. 11/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) PLEASE NOTE IN BOTH SETS OF THE ARCHITECTURAL PLANS |
| | THE PLANS ARE SIGNED AND DATED BY THE ARCHITECT OF |
| | RECORD BUT NOT SEALED. PLEASE SEAL ALL PLANS BEING |
| | SUBMITTED TO THE CITY FOR ISSUANCE. |
| | |
| | FL ADMIN CODE 61G16.003(1) ARCHITECTS. PLANS, |
| | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS PREPARED BY |
| | THE DESIGN PROFESSIONAL AND BEING FILED FOR PUBLIC |
| | RECORD SHALL HAVE THE SIGNATURE AND SEAL OF THE DESIGN |
| | PROFESSIONAL AFFIXED TO THE DOCUMENT. |
| | |
| | 2) COVERSHEET- CS-101: |
| | |
| | 2A) THE COVERSHEET LIST UNDER THE HEADING PROJECT |
| | DESCRIPTION A LEVEL III ALTERATION. PLEASE REVIEW UNDER |
| | THE 2014 EXISTING BUILDING CODE SEE SECTIONS AND |
| | CORRECT: |
| | |
| | EXIST. BLDG CODE 506.1 SCOPE. CHANGE OF OCCUPANCY |
| | PROVISIONS APPLY WHERE THE ACTIVITY IS CLASSIFIED AS A |
| | CHANGE OF OCCUPANCY AS DEFINED IN CHAPTER 2. CHANGE OF |
| | OCCUPANCY. A CHANGE IN THE PURPOSE OR LEVEL OF ACTIVITY |
| | WITHIN A BUILDING THAT INVOLVES A CHANGE IN APPLICATION |
| | OF THE REQUIREMENTS OF THIS CODE. |
| | |
| | EXIST. BLDG. CODE 506.2 APPLICATION. CHANGES OF |
| | OCCUPANCY SHALL COMPLY WITH THE PROVISIONS OF |
| | CHAPTER 10. |
| | |
| | EXIST. BLDG CODE 1001.3.1. PARTIAL CHANGE OF OCCUPANCY |
| | CLASSIFICATION. WHERE A PORTION OF AN EXISTING BUILDING |
| | IS CHANGED TO A NEW OCCUPANCY CLASSIFICATION, SECTION |
| | 1012 SHALL APPLY. |
| | |
| | 2B) THE COVERSHEET DOES NOT PROVIDE ENOUGH DETAIL AS |
| | HOW THE R3 UNIT IS TO BE USED. IF THIS IS UNIT IS A |
| | SINGLE DWELLING UNIT OR TO BE CONSIDERED TWO SLEEPING |
| | UNITS SIMILAR TO DORM UNITS. IF THE INTENT IS TO BE |
| | SIMILAR TO DORMS THEN THE SLEEPING UNITS WILLO NEED TO |
| | BE FIRE RATED , IF THIS IS A SINGLE DWELLING UNIT THEN |
| | THEY DO NOT. |
| | DIFINITION: SLEEPING UNIT. A ROOM OR SPACE IN WHICH |
| | PEOPLE SLEEP, WHICH CAN ALSO INCLUDE PERMANENT |
| | PROVISIONS FOR LIVING, EATING, AND EITHER SANITATION OR |
| | KITCHEN FACILITIES BUT NOT BOTH. SUCH ROOMS AND SPACES |
| | THAT ARE ALSO PART OF A DWELLING UNIT ARE NOT SLEEPING |
| | UNITS. |
| | |
| | DIFINITION: DORMITORY. A SPACE IN A BUILDING WHERE |
| | GROUP SLEEPING ACCOMMODATIONS ARE PROVIDED IN ONE ROOM, |
| | OR IN A SERIES OF CLOSELY ASSOCIATED ROOMS, FOR PERSONS |
| | NOT MEMBERS OF THE SAME FAMILY GROUP, UNDER JOINT |
| | OCCUPANCY AND SINGLE MANAGEMENT, AS IN COLLEGE |
| | DORMITORIES OR FRATERNITY HOUSES. |
| | |
| | PLEASE PROVIDE A BETTER DISCRIPTION OF THE OCCUPANCY |
| | USAGE TO SEE IF UNDER THE 2014 FBC-B SEPARATION WALLS |
| | WOULD BE REQUIRED BETWEEN SLEEPING UNITS, FBC-B 420.2. |
| | |
| | 2C) THE 2ND FLOOR OF THE R3 OCCUPANCY IS ALSO TO BE |
| | CONSIDERED A MIXED OCCUPANCY SINCE THE GYM IS OVER 10 % |
| | OF THE FLOOR PLATE. THE INSIDE DIMENSIONS OF THE |
| | BUILDING GIVE 2026 SQ. FEET. THE GYM IS 435.76 SQ. FT. |
| | OR 21% OF THE FLOOR PLATE, PLEASE PROVIDE COMPLIANCE: |
| | |
| | FBC-B 508.4.1 OCCUPANCY CLASSIFICATION. SEPARATED |
| | OCCUPANCIES SHALL BE INDIVIDUALLY CLASSIFIED IN |
| | ACCORDANCE WITH SECTION 302.1. EACH SEPARATED SPACE |
| | SHALL COMPLY WITH THIS CODE BASED ON THE OCCUPANCY |
| | CLASSIFICATION OF THAT PORTION OF THE BUILDING. TABLE |
| | 508.4. |
| | |
| | 3) SHEET A-103: |
| | 3A) SHEET A-103 INDICATES NEW CASEMENT WINDOW MARKED |
| | WINDOW TYPE A. IN THE WINDOW SCHEDULE AND ON THE PLANS |
| | IT IS DEPICTED AS A CASEMENT WINDOW. THE WINDOW |
| | SCHEDULE INDICATES A MIAMI-DADE NOA 16-0714.23 WHICH |
| | HAS BEEN SUPERCEDED BY 17-0614.20. BOTH NOAS ARE FOR A |
| | PGT MODEL AW-740 A AWNING WINDOW NOT A CASEMENT WINDOW. |
| | PLEASE CORRECT PLANS. 107.2.1.3 ADDITIONAL INFORMATION |
| | WILL BE REQUIRED. SUBMITTED PRODUCT APPROVAL IS FOR |
| | AWNING TYPE WINDOW. |
| | |
| | 3B) SHEET A-103 ALSO HAS THE DOOR SCHEDULE, THE NEW |
| | EXTERIOR DOOR WITH SIDELITE IS IDENTIFIED BY THE |
| | MIAMI-DADE NOA 17-0504.01. PLEASE IDENTIFY THE SIZE OF |
| | THE SIDELITE IN THE SUBMITTED PRODUCT APPROVAL. . THE |
| | PLANS INDICATE THE DOOR IS A OUTSWING DOOR AND THE DOOR |
| | ITSELF IS 3 FEET IN WIDTH, THE OVERALL OPENING IS 6 |
| | FEET WIDE, HOW WIDE IS THE REMAINDER OF THE SIDE LITE |
| | AND FRAME. PLEASE REVIEW THE PRESSURES FOR UNREINFORCED |
| | SIDE LITES SHEET 2 OF 15 AND TABLE 3. PLEASE IDENTIFY |
| | ALL OF THE COMPONENTS OF THE DOOR, SIDE LITE ASSEMBLY |
| | AND ASSCIATED PRESSURES. |
| | IDENTIFY GLAZING/ MULLIONS. PLEASE IDENTIFY ON THE |
| | PRODUCT APPROVAL BEFORE SUBMITTING TO DESIGNER OF |
| | RECORD AND BEFORE SUBMISSION TO THE BUILDING |
| | DEPARTMENT. FOR ALL PRODUCTS WITH GLAZING, PLEASE |
| | IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF GLAZING, |
| | MULLION SIZE, LENGTH IF UNREINFORCED OR REINFORCED |
| | INFORMATION IF REQUIRED, ATTACHMENTS AND ASSOCIATE |
| | PRESSURES FOR EACH OPENING SIZE. 2014 FBC-B 1405.13.1 |
| | INSTALLATION. WINDOWS AND DOORS SHALL BE INSTALLED IN |
| | ACCORDANCE WITH APPROVED MANUFACTURER?S INSTRUCTIONS. |
| | FASTENER SIZE AND SPACING SHALL BE PROVIDED IN SUCH |
| | INSTRUCTIONS AND SHALL BE CALCULATED BASED ON MAXIMUM |
| | LOADS AND SPACING USED IN THE TESTS. |
| | |
| | 3C) THE SHEET A-103 INDICATES THE ASSUMED VASD |
| | PRESSURES BUT THE WIND DESIGN FOR THESE PRESSURES IS |
| | NOT GIVEN. |
| | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. |
| | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL |
| | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE |
| | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE |
| | STRUCTURE: |
| | |
| | 3C) 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND |
| | GUST), MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND |
| | SPEED, VASD, AS DETERMINED IN ACCORDANCE WITH SECTION |
| | 1609.3.1. |
| | |
| | |
| | 3C) 2. RISK CATEGORY. |
| | |
| | 3C)3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. |
| | HEIGHT AND EXPOSURE. |
| | |
| | 3C) 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| | |
| | 3C) 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY |
| | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. |
| | |
| | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| | BUILDING. |
| | |
| | 3D) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, |
| | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT |
| | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, |
| | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS |
| | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT |
| | APPROVALS: |
| | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. |
| | (B) WINDOWS & MULLIONS |
| | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL |
| | LOUVERS, EFIS SYSTEMS |
| | |
| | 3E) SHEET A-103 DETAILS 5 & 6 BOTH SHOW THE USE OF |
| | PAPER BACKED WIRE LATH OVER19/32NDS PLYWOOD. PLEASE ADD |
| | A SECONDARY WATER BARRIER REQUIRED BY 2014 FBC-B |
| | SECTION: |
| | |
| | 2510.6 WATER-RESISTIVE BARRIERS. WATER-RESISTIVE |
| | BARRIERS SHALL BE INSTALLED AS REQUIRED IN SECTION |
| | 1404.2 AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, |
| | SHALL INCLUDE A WATER-RESISTIVE VAPOR-PERMEABLE BARRIER |
| | WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF |
| | GRADE D PAPER. THE INDIVIDUAL LAYERS SHALL BE INSTALLED |
| | INDEPENDENTLY SUCH THAT EACH LAYER PROVIDES A SEPARATE |
| | CONTINUOUS PLANE AND ANY FLASHING (INSTALLED IN |
| | ACCORDANCE WITH SECTION 1405.4) INTENDED TO DRAIN TO |
| | THE WATER-RESISTIVE BARRIER IS DIRECTED BETWEEN THE |
| | LAYERS. |
| | |
| | 3E) SHEET A-103 THE VENT SIZE FOR EGRESS WINDOWS IS |
| | STATED IN QUOTING THE CODE, NOT SHOWING COMPLIANCE. |
| | |
| | 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING |
| | CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3: W.P.B. |
| | ADMINISTRATIVE CODE. SUCH INFORMATION SHALL BE SPECIFIC |
| | TO THE TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE |
| | OR IN PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE |
| | USED AS A SUBSTITUTE FOR SPECIFIC INFORMATION". |
| | CONSTRUCTION DOCUMENTS SHALL BE SUFFICIENT CLARITY TO |
| | INDICATE THE LOCATION, NATURE AND EXTENT OF THE WORK |
| | PROPOSED AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE |
| | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, |
| | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING |
| | OFFICIAL. |
| | |
| | 2014 FBC-B 1029.2 MINIMUM SIZE. EMERGENCY ESCAPE AND |
| | RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING |
| | OF 5.7 SQUARE FEET . |
| | |
| | FBC-B 1029.2.1 MINIMUM DIMENSIONS. |
| | THE MINIMUM NET CLEAR OPENING HEIGHT DIMENSION SHALL BE |
| | 24 INCHES (610 MM). THE MINIMUM NET CLEAR OPENING WIDTH |
| | DIMENSION SHALL BE 20 INCHES (508 MM). THE NET CLEAR |
| | OPENING DIMENSIONS SHALL BE THE RESULT OF NORMAL |
| | OPERATION OF THE OPENING. |
| | |
| | FBC-B 1029.3 MAXIMUM HEIGHT FROM FLOOR. |
| | EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE THE |
| | BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44 INCHES |
| | (1118 MM) MEASURED FROM THE FLOOR. |
| | |
| | 4) SHEET A-101 THE BATHROOMS INDICATE TO INSTALL GREEN |
| | BOARD ON CMU WALLS. PLEASE REVIEW THE 2014 |
| | FBC-B SECTION: |
| | |
| | 2509.2 BASE FOR TILE. GLASS MAT WATER-RESISTANT GYPSUM |
| | BACKING PANELS, DISCRETE NONASBESTOS FIBER-CEMENT |
| | INTERIOR SUBSTRATE SHEETS OR NONASBESTOS FIBER-MAT |
| | REINFORCED CEMENTITIOUS BACKER UNITS IN COMPLIANCE WITH |
| | ASTM C 1178, C 1288 OR C 1325 AND INSTALLED IN |
| | ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS SHALL BE |
| | USED AS A BASE FOR WALL TILE IN TUB AND SHOWER AREAS |
| | AND WALL AND CEILING PANELS IN SHOWER AREAS. |
| | WATER-RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A |
| | BASE FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN |
| | INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C 840 AND |
| | MANUFACTURER RECOMMENDATIONS. REGULAR GYPSUM WALLBOARD |
| | IS PERMITTED UNDER TILE OR WALL PANELS IN OTHER WALL |
| | AND CEILING AREAS WHEN INSTALLED IN ACCORDANCE WITH |
| | GA-216 OR ASTM C 840. |
| | 2509.3 LIMITATIONS. |
| | WATER-RESISTANT GYPSUM BACKING BOARD SHALL NOT BE USED |
| | IN THE FOLLOWING LOCATIONS: |
| | 1. OVER A VAPOR RETARDER IN SHOWER OR BATHTUB |
| | COMPARTMENTS. |
| | 2. WHERE THERE WILL BE DIRECT EXPOSURE TO WATER OR IN |
| | AREAS SUBJECT TO CONTINUOUS HIGH HUMIDITY. |
| | 3. ON CEILINGS WHERE FRAME SPACING EXCEEDS 12 INCHES |
| | (305 MM) O.C. FOR 1/2-INCH THICK (12.7 MM) |
| | WATER-RESISTANT GYPSUM BACKING BOARD AND MORE THAN 16 |
| | INCHES (406 MM) O.C. FOR 5/8-INCH THICK (15.9 MM) |
| | WATER-RESISTANT GYPSUM BACKING BOARD. |
| | |
| | 5) BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT |
| | FEES MUST BE PAID TO PALM BEACH COUNTY. ONE SET OF |
| | PLANS WILL HAVE TO BE TAKEN (BY THE CONTRACTOR OR |
| | REPRESENTATIVE) TO THE PALM BEACH COUNTY IMPACT FEE |
| | OFFICE LOCATED AT 2300 N. JOG RD. ROOMS 2W01-2W14 WEST |
| | PALM BEACH, FL. THE ACTUAL PERMIT SET OF PLANS MUST BE |
| | STAMPED BY THAT OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. PLEASE CALL |
| | (561)233-5025 FOR MORE INFORMATION. |
| | |
| | 6) A TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW |
| | COMMENT NUMBER, WITH A DESCRIPTION OF THE REVISION |
| | MADE, IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE |
| | THE CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR |
| | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |
| | |